HP bc1000 Setup & Installation Guide - Page 113
Setup and Installation Guide, Troubleshooting, card or blade system board has
View all HP bc1000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Troubleshooting Table D-11: Is the Health LED on the Blade PC Green? (Continued) Answer Possible Reasons Possible Solutions No, it blinks red five times, once per second, followed by a two second pause. SODIMM(s) may not be seated correctly, SODIMM(s) may be bad, or blade system board may be bad. Check to see if memory is present. If so, then try re-seating the memory and rebooting. If the error still occurs then try replacing the memory. Replace the system board if the new memory produces the same failure result. No, it blinks red six times, once per second, followed by a two second pause. The optional graphics diagnostic card or blade system board has failed. Replace the optional graphics diagnostic card. If the condition still exists, replace the system board. No, it blinks red seven times, once per second, followed by a two second pause. The blade system board has failed. Replace the system board. Yes, it is green. If the health LED on the Blade PC is green, go to Table D-12. Setup and Installation Guide www.hp.com D-19