Installing and Cabling the HP CCI Solution 5. Repeat steps 1 through 4 for each Blade PC enclosure you have installed. Null-Modem Cable If you are cabling a serial device such as a laptop computer to the console connector on the Integrated Administrator, be sure that you use the null-modem cable provided with the enclosure and not a straight-through cable. Use the following table to determine the specifications of this cable. Cable Pinout for a Null-Modem Cable Signal Name EM PIN DB-9 PIN TxD 3 2 RxD 2 3 RTS 7 8 CTS 8 7 GND 5 5 DSR 6 4 CD 1 4 DTR 4 1 & 6 TxD 3 2 DB-25 PIN 3 2 5 4 7 20 20 6 & 8 3 Setup and Installation Guide www.hp.com 4-17
Setup and Installation Guide
www.hp.com
4-17
Installing and Cabling the HP CCI Solution
5. Repeat steps 1 through 4 for each Blade PC enclosure you have
installed.
Null-Modem Cable
If you are cabling a serial device such as a laptop computer to the
console connector on the Integrated Administrator, be sure that you
use the null-modem cable provided with the enclosure and not a
straight-through cable. Use the following table to determine the
specifications of this cable.
Cable Pinout for a Null-Modem Cable
Signal Name
EM PIN
DB-9 PIN
DB-25 PIN
TxD
3
2
3
RxD
2
3
2
RTS
7
8
5
CTS
8
7
4
GND
5
5
7
DSR
6
4
20
CD
1
4
20
DTR
4
1 & 6
6 & 8
TxD
3
2
3