IBM 8478 Hardware Maintenance Manual - Page 126
Processor, board, ServeRAID, Undetermined, problems
![]() |
UPC - 087944650553
View all IBM 8478 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 126 highlights
Processor board LEDs Table 16. LED Fan Memory CPU VRM Cause 1. Replace the fan assembly. 1. Replace the DIMM indicated by the lit DIMM error. 1. If a microprocessor LED is on for a microprocessor connector that has a terminator card installed instead of a microprocessor, the microprocessors are not installed in the correct order. See "Removing and installing a microprocessor" on page 63 for information about the correct order for installing microprocessors and VRMs. 2. Turn off the server, reseat the microprocessor, and restart the server. 3. Replace the microprocessor. 1. Turn off the server, reseat the VRM indicated by the lit VRM error LED, and restart the server. 2. Replace the VRM ServeRAID For ServeRAID error codes and procedures, refer to the Hardware Maintenance Manual for the particular RAID adapter in the system being serviced. Undetermined problems You are here because the diagnostic tests did not identify the failure, the Devices List is incorrect, or the system is inoperative. Note: A corrupt CMOS can cause undetermined problems. If power problems are suspected: 1. Power-off the computer. 2. Be sure the system is cabled correctly. 3. Remove or disconnect the following (one at a time) until you find the failure (power-on the computer and reconfigure each time). v Any external devices v Surge suppressor device (on the computer) v Modem, printer, mouse, or non-IBM devices v Each adapter v Drives 116 Hardware Maintenance Manual: xSeries 200
![](/manual_guide/products/ibm-8478-hardware-maintenance-manual-4ca71d5/126.png)