Icom IC-7610 Instruction Manual basic - Page 76
X-verter, Ant 1 / Ant 2, Rx-ant In/out
View all Icom IC-7610 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
13 CONNECTOR INFORMATION X-VERTER Outputs HF frequency signals for the Transverter operation. ••Input/Output impedance: 50 Ω (unbalanced) ••Output signal level: More than -20 dBm LSet the "Transverter Function" item to ON to use the transverter operating mode. MENU » SET > Function > Transverter Function ••You cannot select the antenna or use the internal antenna tuner while the Transverter function is ON. LSet the offset frequency for the transverter operation. MENU » SET > Function > Transverter Offset ANT 1 / ANT 2 Connect a 50 Ω antenna for the HF to 50 MHz frequency band. ••Input/Output impedance: 50 Ω (unbalanced) RX-ANT IN/OUT Connect a receive antenna to [RX-ANT IN], and a receiver to [RX-ANT OUT]. ••Input/Output impedance: 50 Ω (unbalanced) ••Connector type: BNC LSignal is directly received through [RX-ANT IN], instead of the antenna connector. You can also connect an external preamp or filter, as shown below. LIn this case, set the antenna connector to "ANT 1/R" or "ANT 2/R." (p. 7-1) Example Transmitter TX [ANT 1] [ANT 2] RX [RX-ANT] OUT Filter IN MAIN receiver SUB receiver LIf you are using the AH-4, connect it to [ANT 1]. 13-6