LED Information

Page 62 highlights

LED Information The Intel® Server Board 5500BC includes LEDs that can aid in troubleshooting your system. The following lists these LEDs with a description of their use. LED Name ID System fault Function Aid in server function from the back panel Visible fault warning Location Front Panel and board rear left corner Front panel and board rear left corner LED Color Blue Green or Amber IDE activity Memory fault 1-8 POST code 1-8 Fan Pack Fault CPU 1 & 2 Fan Fault CPU 1 & 2 Fault 5v Standby Power LED Front panel Identify failing memory module Display boot 80 POST code Warn on fan failure Identify fan failure Identify processor failure Identify 5 V standby power on state Identify the power state of the system Front panel and board left side DIMM end front of board Left rear of board Front center board Front center board 1 inch behind processor socket Front left board Front Panel Green Amber Each LED can be Off, Green, Amber, Red Amber Amber Amber Amber Green Notes Press ID LED button or user Server Management software to turn off the LED. • On = No Fault • Green Blink = degraded • Amber = critical error or non-recoverable • Amber blink = non-critical Blinking = Activity. No action required. On = Fault See the POST code table On = Fault On = Fault On = Fault On = 5 V standby power on • Off = Power is off (off or S5) • On = Power on or S0) • Slow Blink = Low power state (S1 - S3) 42 Intel® Server Board S5500BC User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86

42
Intel
®
Server Board S5500BC User’s Guide
LED Information
The Intel
®
Server Board 5500BC includes LEDs that can aid in troubleshooting your
system. The following lists these LEDs with a description of their use.
LED Name
Function
Location
LED Color
Notes
ID
Aid in server function
from the back panel
Front Panel
and board
rear left
corner
Blue
Press ID LED button or user
Server Management software
to turn off the LED.
System fault
Visible fault warning
Front panel
and board
rear left
corner
Green or
Amber
On = No Fault
Green Blink = degraded
Amber = critical error or
non-recoverable
Amber blink = non-critical
IDE activity
Front panel
Front panel
and board left
side
Green
Blinking = Activity. No action
required.
Memory fault 1-8
Identify failing
memory module
DIMM end
front of board
Amber
On = Fault
POST code 1-8
Display boot 80 POST
code
Left rear of
board
Each LED
can be Off,
Green,
Amber, Red
See the POST code table
Fan Pack Fault
Warn on fan failure
Front center
board
Amber
On = Fault
CPU 1 & 2 Fan
Fault
Identify fan failure
Front center
board
Amber
On = Fault
CPU 1 & 2 Fault
Identify processor
failure
1 inch behind
processor
socket
Amber
On = Fault
5v Standby
Identify 5 V standby
power on state
Front left
board
Amber
On = 5 V standby power on
Power LED
Identify the power
state of the system
Front Panel
Green
Off = Power is off (off or
S5)
On = Power on or S0)
Slow Blink = Low power
state (S1 - S3)