JVC GY-DV550E Instruction Manual - Page 80

PROCESS Screen

Page 80 highlights

12. SETUP MENU 12-6 PROCESS Screen Item MASTER BLACK Function, Operation Variation Range Initial Setting Adjusts the pedestal level (master black), which is the reference of black. • To increase the pedestal level ...... Increase the number. (UP) • To decrease the pedestal level .... Decrease the number. (DOWN) MAX (100) 99 201 gradations to NORMAL (0) to -99 MIN (-100) NORMAL DETAIL Adjusts the detail enhancement level. • To sharpen details Increase the number. (UP) • To soften details Decrease the number. (DOWN) MAX (7) 6 15 gradations to NORMAL (0) to -6 MIN (-7) NORMAL DTL. V/H BAL Sets the direction, horizontal (H) or vertical (V), in which stronger detail enhancement is applied. To strengthen the H enhancement ... .. Increase the number (UP). To strengthen the V enhancement ... .. Decrease the number (DOWN). Note: While the LOLUX function is operating, the setting value is fixed at NORMAL and "FIX" is displayed. H-MAX (4) 3 9 gradations to NORMAL (0) to -3 H-MIN (-4) NORMAL DTL. FREQUENCY Varies the detail enhancement level by changing the detail enhancement frequency. Set in accordance with the subject HIGH Applies strong detail enhancement. Used to shoot subjects with fine patterns. MIDDLE ........ Applies medium detail enhancement. LOW Applies weak detail enhancement. Note: Used to shoot subjects with large patterns. While the LOLUX function is operating, the setting value is fixed at MIDDLE and "FIX" is displayed. HIGH MIDDLE LOW LOW SKIN DTL DETECT Sets the Skin Detail function to ON or OFF. ON Skin Detail function activated. OFF Skin Detail function not activated. See "Using the Skin Detail Function" on page 91. ON OFF V. RESOLUTION Increases the vertical resolution. • NORMAL .... Vertical resolution 380 lines. • V.MAX ......... Vertical resolution 450 lines (The sensitivity is degraded and the bright sections may be colored depending on the subject.) NORMAL V.MAX KNEE POINT Sets the knee point (brightness level) when the AUTO KNEE function is set to OFF. 80% 85% 90% 95% 100% ADVANCED PROCESS Displays the ADVANCED PROCESS Screen. See "ADVANCED PROCESS Screen" on page 81. PAGE BACK The CAMERA MENU returns when the SHUTTER dial is pressed with - the cursor at this position. 80 OFF NORMAL 100% -

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

12. SETUP MENU
80
MASTER
BLACK
DETAIL
DTL. V/H
BAL
DTL.
FREQUENCY
SKIN DTL
DETECT
V.
RESOLUTION
KNEE
POINT
ADVANCED
PROCESS
PAGE BACK
NORMAL
NORMAL
NORMAL
LOW
OFF
NORMAL
100%
12-6
PROCESS Screen
Item
Function, Operation
Variation Range
Initial Setting
Adjusts the pedestal level (master black), which is the reference of black.
• To increase the pedestal level
......
Increase the number. (UP)
• To decrease the pedestal level
....
Decrease the number. (DOWN)
Adjusts the detail enhancement level.
• To sharpen details
.......................
Increase the number. (UP)
• To soften details
...........................
Decrease the number. (DOWN)
Sets the direction, horizontal (H) or vertical (V), in which stronger detail
enhancement is applied.
To strengthen the H enhancement
... ..
Increase the number (UP).
To strengthen the V enhancement
... ..
Decrease the number (DOWN).
While the LOLUX function is operating, the setting value is fixed at
NORMAL and “FIX” is displayed.
Varies the detail enhancement level by changing the detail enhancement
frequency. Set in accordance with the subject
HIGH
.............
Applies strong detail enhancement.
Used to shoot subjects with fine patterns.
MIDDLE
........
Applies medium detail enhancement.
LOW
..............
Applies weak detail enhancement.
Used to shoot subjects with large patterns.
While the LOLUX function is operating, the setting value is fixed at
MIDDLE and “FIX” is displayed.
Sets the Skin Detail function to ON or OFF.
ON
................
Skin Detail function activated.
OFF
...............
Skin Detail function not activated.
See "Using the Skin Detail Function" on page 91.
Increases the vertical resolution.
• NORMAL
....
Vertical resolution 380 lines.
• V.MAX
.........
Vertical resolution 450 lines
(The sensitivity is degraded and the bright sections may be colored
depending on the subject.)
Sets the knee point (brightness level) when the AUTO KNEE function is
set to OFF.
Displays the ADVANCED PROCESS Screen.
See "ADVANCED PROCESS Screen" on page 81.
The CAMERA MENU returns when the SHUTTER dial is pressed with
the cursor at this position.
MAX (100)
99
201
gradations
to
NORMAL (0)
to
-99
MIN (-100)
MAX (7)
6
15
gradations
to
NORMAL (0)
to
-6
MIN (-7)
H-MAX (4)
3
9
gradations
to
NORMAL (0)
to
-3
H-MIN (-4)
HIGH
MIDDLE
LOW
ON
OFF
NORMAL
V.MAX
80%
85%
90%
95%
100%
Note:
Note: