Page 82 highlights
Diagnostic Error Code 001-038-XXX System Extension failure 001-039-XXX System DMI data structure error 001-040-XXX System IRQ failure 001-041-XXX System DMA failure 001-195-XXX System Test aborted by user 001-196-XXX System test halt, error threshold exceeded 001-197-XXX System test warning 001-198-XXX System test aborted 001-199-XXX System test failed, cause unknown 001-250-XXX System ECC error 001-254-XXX 001-255-XXX 001-256-XXX 001-257-XXX System DMA error 001-260-XXX 001-264-XXX System IRQ error 001-268-XXX System IRQ1 failure 001-269-XXX System IRQ2 failure 001-270-XXX System IRQ3 failure FRU/Action 1. Adapter card 2. System board 1. Flash the system 2. System board 1. Power-off/on system and re-test 2. System board 1. Power-off/on system and re-test 2. System board 1. Information 2. Re-start the test, if necessary 1. Press F3 to review the log file 2. Re-start the test to reset the log file 1. Make sure the component that is called out is connected and/or enabled 2. Re-run test 3. Component that is called out in warning statement 4. Component under test 1. If a component is called out, make sure it is connected and/or enabled 2. Flash the system and re-test 3. Go to the ″Undetermined problems″ section 1. Go to the ″Undetermined problems″ section 2. Flash the system and re-test 3. Replace component under function test 1. System board 1. System board 1. System board 1. Device on IRQ1 2. System board 1. Device on IRQ2 2. System board 1. Device on IRQ3 2. System board 74 Hardware Maintenance Manual