Netgear FS728TPv1 FS728TP User Manual - Page 68

Trap Filter Settings, Filter Name, Object ID Subtree, Apply, System > SNMP > SNMPv3, Delete

Page 68 highlights

FS728TP Smart Switch FS728TP Smart Switch Software Administration Manual The SNMPv3 Trap Filter Content screen contains the following fields: Trap Filter Settings • Filter Name - Contains a list of user-defined notification filters. Trap Filter Settings • Object ID Subtree - Enter the OID for which notifications are sent or blocked. If a filter is attached to an OID, traps or informs are generated and sent to the trap recipients. OIDs are selected from either the Select field or the Object ID field. • Filter Type - Select whether to send traps or informs relating to the selected OID. The possible field values are: - Excluded - Does not send traps or informs. - Included - Sends traps or informs. 2. Select the Filter Name from the list in the provided field. 3. Select the trap filter content entry from the OID table. 4. Enter the Object ID Subtree in the provided field in the first row. 5. Select the Filter Type from the list in the provided field in the first row. 6. Click Apply to update the device. To add a new trap filter content entry: 1. Click System > SNMP > SNMPv3 > Trap Filter Content. The SNMPv3 Trap Filter Content screen displays. 2. Select the Filter Name from the list in the provided field. 3. Enter the Object ID Subtree in the provided field in the first row. 4. Select the Filter Type from the list in the provided field in the first row. 5. Click Add to update the device. To remove a trap filter content entry: 1. Click System > SNMP > SNMPv3 > Trap Filter Content. The SNMPv3 Trap Filter Content screen displays. 2. Select the Filter Name from the list in the provided field. 3. Select the trap filter content entry. 4. Click Delete to remove the entry. Managing System Settings v1.0, December 2007 3-32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185

FS728TP Smart Switch FS728TP Smart Switch Software Administration Manual
Managing System Settings
3-32
v1.0, December 2007
The SNMPv3 Trap Filter Content screen contains the following fields:
Trap Filter Settings
Filter Name
– Contains a list of user-defined notification filters.
Trap Filter Settings
Object ID Subtree
– Enter the OID for which notifications are sent or blocked. If a filter
is attached to an OID, traps or informs are generated and sent to the trap recipients. OIDs
are selected from either the Select field or the Object ID field.
Filter Type
– Select whether to send traps or informs relating to the selected OID. The
possible field values are:
Excluded – Does not send traps or informs.
Included – Sends traps or informs.
2.
Select the
Filter Name
from the list in the provided field.
3.
Select the trap filter content entry from the OID table.
4.
Enter the
Object ID Subtree
in the provided field in the first row.
5.
Select the
Filter Type
from the list in the provided field in the first row.
6.
Click
Apply
to update the device.
To add a new trap filter content entry:
1.
Click
System > SNMP > SNMPv3
>
Trap Filter Content
. The SNMPv3 Trap Filter Content
screen displays.
2.
Select the
Filter Name
from the list in the provided field.
3.
Enter the
Object ID Subtree
in the provided field in the first row.
4.
Select the
Filter Type
from the list in the provided field in the first row.
5.
Click
Add
to update the device.
To remove a trap filter content entry:
1.
Click
System > SNMP > SNMPv3
>
Trap Filter Content
. The SNMPv3 Trap Filter Content
screen displays.
2.
Select the
Filter Name
from the list in the provided field.
3.
Select the trap filter content entry.
4.
Click
Delete
to remove the entry.