Netgear WN802Tv2 Reference Manual - Page 29
Data Rates for Channel Width=20MHz and Guard Interval=short 400ms - client mode
UPC - 606449058505
View all Netgear WN802Tv2 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
NETGEAR Wireless-N Access Point WN802T v2 Reference Manual - If using multiple access points, it is better if adjacent access points use different channels to reduce interference. NETGEAR recommends a channel spacing of 5 channels (for example, channels 1, 6, and 11). between adjacent access points. - Wireless stations normally scan all channels, looking for an access point. If more than one access point can be used, the one with the strongest signal is used. This can only happen when the various access points are using the same SSID. • MCS Index/Data Rate. From the pull-down menu, select the available transmit data rate of the wireless network. Also, depending on the band selected, the set of rates will vary. (When Auto Channel is enabled in the 802.11ng mode, then the default Channel Width mode is 20MHz). The possible data rates supported are: • Data Rates for Channel Width=20MHz and Guard Interval=short (400ms): Best, 7.2, 14.4, 21.7, 28.9, 43.3, 57.8, 65, 72.2, 14.44, 28.88, 43.33, 57.77, 86.66, 115.56, 130, & 144.44 Mbps • Data Rates for Channel Width=20MHz and Guard Interval=long (800ms): Best, 6.5, 13, 19.5, 26, 39, 52, 58.5, 65, 13, 26, 39, 52, 78, 104, 117, & 130 Mbps • Data Rates for Channel Width=40MHz and Guard Interval=short: Best, 15, 30, 45, 60, 90, 120, 135, 150, 30, 60, 90, 120, 180, 240, 270, & 300 Mbps • Data Rates for Channel Width=40MHz and Guard Interval=long: Best, 13.5, 27, 40.5, 54, 81, 108, 121.5, 135, 27, 54, 81, 108, 162, 216 Mbps, 243, & 270 Mbps The default is Best, which is the optimal setting. • Channel Width. From the pull-down menu, select the desired channel width. • 20 MHz - This is the static, legacy mode. It gives the least throughput. • 40 MHz - This is the static, high-throughput mode. • 20/40 MHz - This is the dynamic, compatibility mode. Legacy clients can operate at 20 MHz and 11n clients can operate at 40 MHz. • Guard Interval. From the pull-down menu, select the desired guard interval. The guard interval protects from interference from other transmissions. The default is Auto. • Output Power. From the pull-down menu, select the transmit power of the access point. The options are Full, Half, Quarter, Eighth, and Minimum. Decrease the transmit power if two or more APs are close together and use the same channel frequency. The default is Full. (The transmit power may vary depending on the local regulatory regulations). 3. Click Apply to save your wireless settings. Installation and Configuration 2-9 v1.0, September 2008