Panasonic AJSD755 AJSD755 User Guide - Page 39

<INTERFACE&gt, PARALLEL 25P connector.

Page 39 highlights

Setup menus USER menu No./Item Description 200 PARA RUN 201 9P SEL This selects whether two or more VTRs are to be operated in synchronization. 0000 DIS : No operation in synchronization 0001 ENA : Operation in synchronization When operating two or more VTRs in synchronization, set all the VTRs to ENA. This selects whether the REMOTE (9P) connector functions when the CONTROL switch has been set to REMOTE. 202 ID SEL 203 25P SEL 0000 0001 OFF : Connector does not function. ON : Connector functions. This sets the ID information to be returned to the controller. 0000 OTHER 0001 DVCPRO 0002 ORIG OID information of any VTR except for the DVCPRO's is set in OTHER. OThe ORIG setting should only be used when a Panasonic controller (AG-A850 etc. sold separately) is connected. This selects whether the PARALLEL (25P) connector functions when the CONTROL switch has been set to REMOTE. 204 RS232C SEL 0000 0001 OFF : Connector does not function. ON : Connector functions. This selects whether the RS-232C connector functions when the CONTROL switch has been set to REMOTE. 205 BAUD RATE 206 DATA LENGTH 207 STOP BIT 0000 0001 OFF : Connector does not function. ON : Connector functions. These settings are for selecting the RS-232C communication speed (baud rate). 0000 0001 0002 0003 0004 0005 300 600 1200 2400 4800 9600 These settings are for selecting the RS-232C data length. (Unit: bit) 0000 7 0001 8 These settings are for selecting the RS-232C stop bit length. (Unit: bit) 0000 1 0001 2 No./Item Description 208 PARITY 209 RETURN ACK These settings are for selecting the none, odd or even for the RS-232C parity bit. 0000 NON : Parity bit is not used. 0001 ODD: An odd number of bits is used for the parity system. 0002 EVEN: An even number of bits is used for the parity system. These settings are for selecting whether the ACK code is to be returned when a command is received from RS-232C. 210 25P STBY CMD 211 LOCAL 25P 0000 0001 OFF : ACK code is not returned. ON : ACK code is returned. For selecting the method used to detect the STANDBY COMMAND signal input at the PARALLEL (25P) connector. 0000 OFF/ON : Each time active signals are detected, the STANDBY ON or STANDBY OFF mode is selected alternately. 0001 ON : When active signals are detected in the STANDBY OFF mode, the unit is transferred to the STANDBY ON mode. Nothing happens if they are detected during an operation in the STANDBY ON mode. This selects whether the PARALLEL (25P) connector is to function when the CONTROL switch is at the LOCAL position. 212 MASTER PORT 0000 0001 OFF : Connector does not function. ON : Connector functions. For selecting the remote control connector to control the slave when the unit is used as the master during deck-to-deck operations. 0000 IN/OUT : The IN/OUT connector is used. 0001 OUT : The OUT connector is used. This menu item takes effect only when the CONTROL switch has been set to the LOCAL position. The underlined items indicates the initial setting. 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

39
Setup menus
The underlined items indicates the initial setting.
USER menu
<INTERFACE>
No./Item
Description
200
PARA RUN
This selects whether two or more VTRs are to
be operated in synchronization.
0000
DIS
:
No operation in synchronization
0001
ENA
:
Operation in synchronization
<Note>
When
operating
two
or
more
VTRs
in
synchronization, set all the VTRs to ENA.
202
ID SEL
This sets the ID information to be returned to
the controller.
0000
OTHER
0001
DVCPRO
0002
ORIG
<Notes>
O
ID information of any VTR except for the
DVCPRO’s is set in OTHER.
O
The ORIG setting should only be used when a
Panasonic controller (AG-A850 etc. sold
separately) is connected.
203
25P SEL
This selects whether the PARALLEL (25P)
connector functions when the CONTROL
switch has been set to REMOTE.
0000
OFF
:
Connector does not function.
0001
ON
:
Connector functions.
205
BAUD RATE
These settings are for selecting the RS-232C
communication speed (baud rate).
0000
300
0001
600
0002
1200
0003
2400
0004
4800
0005
9600
204
RS232C SEL
This selects whether the RS-232C connector
functions when the CONTROL switch has
been set to REMOTE.
0000
OFF
:
Connector does not function.
0001
ON
:
Connector functions.
206
DATA
LENGTH
These settings are for selecting the RS-232C
data length.
(Unit: bit)
0000
7
0001
8
207
STOP BIT
These settings are for selecting the RS-232C
stop bit length.
(Unit: bit)
0000
1
0001
2
201
9P SEL
This selects whether the REMOTE (9P)
connector functions when the CONTROL
switch has been set to REMOTE.
0000
OFF
:
Connector does not function.
0001
ON
:
Connector functions.
208
PARITY
These settings are for selecting the none, odd
or even for the RS-232C parity bit.
0000
NON
:
Parity bit is not used.
0001
ODD
:
An odd number of bits is used for the parity
system.
0002
EVEN
:
An even number of bits is used for the parity
system.
No./Item
Description
209
RETURN ACK
These settings are for selecting whether the
ACK code is to be returned when a command
is received from RS-232C.
0000
OFF
:
ACK code is not returned.
0001
ON
:
ACK code is returned.
210
25P STBY
CMD
For selecting the method used to detect the
STANDBY COMMAND signal input at the
PARALLEL (25P) connector.
0000
OFF/ON
:
Each time active signals are detected, the
STANDBY ON or STANDBY OFF mode is
selected alternately.
0001
ON
:
When active signals are detected in the
STANDBY OFF mode, the unit is transferred to
the STANDBY ON mode.
Nothing happens if they are detected during an
operation in the STANDBY ON mode.
212
MASTER
PORT
For selecting the remote control connector to
control the slave when the unit is used as the
master during deck-to-deck operations.
0000
IN/OUT
:
The IN/OUT connector is used.
0001
OUT
:
The OUT connector is used.
<Note>
This menu item takes effect only when the
CONTROL switch has been set to the LOCAL
position.
211
LOCAL 25P
This selects whether the PARALLEL (25P)
connector is to function when the CONTROL
switch is at the LOCAL position.
0000
OFF
:
Connector does not function.
0001
ON
:
Connector functions.