Panasonic AJSD755 AJSD755 User Guide - Page 39
<INTERFACE>, PARALLEL 25P connector.
View all Panasonic AJSD755 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Setup menus USER menu No./Item Description 200 PARA RUN 201 9P SEL This selects whether two or more VTRs are to be operated in synchronization. 0000 DIS : No operation in synchronization 0001 ENA : Operation in synchronization When operating two or more VTRs in synchronization, set all the VTRs to ENA. This selects whether the REMOTE (9P) connector functions when the CONTROL switch has been set to REMOTE. 202 ID SEL 203 25P SEL 0000 0001 OFF : Connector does not function. ON : Connector functions. This sets the ID information to be returned to the controller. 0000 OTHER 0001 DVCPRO 0002 ORIG OID information of any VTR except for the DVCPRO's is set in OTHER. OThe ORIG setting should only be used when a Panasonic controller (AG-A850 etc. sold separately) is connected. This selects whether the PARALLEL (25P) connector functions when the CONTROL switch has been set to REMOTE. 204 RS232C SEL 0000 0001 OFF : Connector does not function. ON : Connector functions. This selects whether the RS-232C connector functions when the CONTROL switch has been set to REMOTE. 205 BAUD RATE 206 DATA LENGTH 207 STOP BIT 0000 0001 OFF : Connector does not function. ON : Connector functions. These settings are for selecting the RS-232C communication speed (baud rate). 0000 0001 0002 0003 0004 0005 300 600 1200 2400 4800 9600 These settings are for selecting the RS-232C data length. (Unit: bit) 0000 7 0001 8 These settings are for selecting the RS-232C stop bit length. (Unit: bit) 0000 1 0001 2 No./Item Description 208 PARITY 209 RETURN ACK These settings are for selecting the none, odd or even for the RS-232C parity bit. 0000 NON : Parity bit is not used. 0001 ODD: An odd number of bits is used for the parity system. 0002 EVEN: An even number of bits is used for the parity system. These settings are for selecting whether the ACK code is to be returned when a command is received from RS-232C. 210 25P STBY CMD 211 LOCAL 25P 0000 0001 OFF : ACK code is not returned. ON : ACK code is returned. For selecting the method used to detect the STANDBY COMMAND signal input at the PARALLEL (25P) connector. 0000 OFF/ON : Each time active signals are detected, the STANDBY ON or STANDBY OFF mode is selected alternately. 0001 ON : When active signals are detected in the STANDBY OFF mode, the unit is transferred to the STANDBY ON mode. Nothing happens if they are detected during an operation in the STANDBY ON mode. This selects whether the PARALLEL (25P) connector is to function when the CONTROL switch is at the LOCAL position. 212 MASTER PORT 0000 0001 OFF : Connector does not function. ON : Connector functions. For selecting the remote control connector to control the slave when the unit is used as the master during deck-to-deck operations. 0000 IN/OUT : The IN/OUT connector is used. 0001 OUT : The OUT connector is used. This menu item takes effect only when the CONTROL switch has been set to the LOCAL position. The underlined items indicates the initial setting. 39