Pfaff creative 4874 Owner's Manual - Page 23

needles, Cat. No. 2002. - overlock

Page 23 highlights

B A K Technical section, general Changing a needle Turn off at the power switch To remove: Lower the presser foot and raise the needle(s) to its/their highest position. Take the needle changing tool out of the accessory box and push it up over the needle as far as it will go. Loosen (but do not remove) the needle's retaining screw with the allen key and pull the needle out from below. To insert: Insert the needle in hole A of the needle changing tool so that the flat side K of the needle is opposite face B of the tool. Insert the needle as far as it will go into the needle holder (you may have to push a little harder by hand) and tighten the retaining screw. Remove the needle changing tool. The 4874 uses system EL X 705 overlock needles, Cat. No. 2002. 2-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144

2-9
Technical section, general
Changing a needle
Turn off at the power switch
To remove:
Lower the presser foot and
raise the needle(s) to its/their highest
position. Take the needle changing tool
out of the accessory box and push it up
over the needle as far as it will go. Loosen
(but do not remove) the needle’s retaining
screw with the allen key and pull the
needle out from below.
To insert:
Insert the needle in hole A of the
needle changing tool so that the flat side
K of the
needle is opposite face B of the
tool. Insert the needle as far as it will go
into the needle holder (you may have to
push a little harder by hand) and tighten
the retaining screw. Remove the needle
changing tool.
The 4874 uses system EL X 705 overlock
needles, Cat. No. 2002.
B
A
K