Sharp PN-V701 PN-V701 Operation Manual - Page 37

Initialization (Reset)/Functional Restriction Setting (FUNCTION

Page 37 highlights

Initialization (Reset)/Functional Restriction Setting (FUNCTION) You can return the settings to their factory-preset values and restrict operations. 1. If using the remote control unit: Press the FUNCTION button, and then press the MENU button within 10 seconds. If using the monitor buttons: Press the MENU button and INPUT button at the same time until "F" is displayed in the upper left area of the screen, then while "F" is being displayed, press the MENU button. FUNCTION ALL RESET ADJUSTMENT LOCK ADJUSTMENT LOCK TARGET RS-232C/LAN OSD DISPLAY OFF UNLOCKED ON 1 LED ON TEMPERATURE ALERT LED STATUS ALERT LED POWER BUTTON MONITOR EXTERNAL CONTROLLER INPUT SIGNAL RESPONSE LEVEL 1 OK:[ENTER] END:[RETURN] 2. Select and set the items. ALL RESET Resets the settings to the factory default settings. Press the ENTER button, select the resetting method, and then press the ENTER button. After initialization, turn the main power switch off and then back on. ALL RESET1 Resets all the settings to the factory default settings. ALL RESET2 Returns all settings to the factory default settings except for the following items: LAN SETUP, RS-232C/LAN SELECT, ID No. SET, REMOTE No., BAUD RATE, NETWORK, MAIL, SERVICE & SUPPORT, and SNMP (See page 29, and pages 55 to 58.) ADJUSTMENT LOCK You can disable operations on the monitor and the remote control unit that use buttons. OFF ���Enables operation. ON 1 ��Disables all operations other than turning power on/off and FUNCTION. ON 2 ��Only the FUNCTION operation is enabled. Disables all operations other than FUNCTION (not even power on/off). ADJUSTMENT LOCK TARGET Sets the target to prohibit operation of with ADJUSTMENT LOCK. REMOTE CONTROL Prohibits remote control operation MONITOR BUTTONS ��� Prohibits monitor button operation BOTH Prohibits remote control and monitor button operation RS-232C/LAN Specifies whether to allow control via RS-232C or LAN (see pages 38 and 51). OSD DISPLAY Shows/hides the menu, modes and messages. The FUNCTION and REMOTE CONTROL MODE screens cannot be hidden. ON 1 Shows all menus, modes and messages. ON 2 Hides messages automatically displayed by the display. Shows messages during operation. OFF Hides all menus, modes and messages. LED Specifies whether to light the power LED. TEMPERATURE ALERT Selects the notification method for an abnormal temperature. OFF Do not notify about an abnormal temperature. OSD & LED �� When an abnormal temperature is detected, the power LED flashes in red and green alternately and the screen displays a message: TEMPERATURE. LED When an abnormal temperature is detected, the power LED flashes in red and green alternately. STATUS ALERT Selects the notification method for a hardware error. OFF Do not notify about the error. OSD & LED �� When a hardware error is detected, the power LED flashes in red and the screen displays a message: STATUS [xxxx]. LED When a hardware error is detected, the power LED flashes in red. POWER BUTTON Normally, leave this setting as MONITOR. When using an optional part, if instruction appears, change the setting accordingly. EXTERNAL CONTROLLER INPUT Normally, you do not need to change this setting. When using an optional part, if instruction appears, change the setting accordingly. SIGNAL RESPONSE LEVEL Normally, you do not need to change this setting. Use this option to set the level of response to signal changes. 3. Press the RETURN button to return to the normal screen. TIPS • When both abnormal temperature and hardware error are detected, the hardware error notification overrides. • If TEMPERATURE ALERT or STATUS ALERT is set to OSD&LED, alert messages will appear even if the OSD DISPLAY is set to ON 2 or OFF. • If TEMPERATURE ALERT or STATUS ALERT is set to LED or OSD & LED, the LED lights even if the LED function is set to OFF. 37 E

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70

37
E
You can return the settings to their factory-preset values and
restrict operations.
1. If using the remote control unit:
Press the FUNCTION button, and then press the MENU
button within 10 seconds.
If using the monitor buttons:
Press the MENU button and INPUT button at the same
time until “F” is displayed in the upper left area of the
screen, then while “F” is being displayed, press the
MENU button.
▲▲▲▲▲▲
OFF
UNLOCKED
ON 1
ON
LED
LED
MONITOR
1
FUNCTION
ALL RESET
ADJUSTMENT LOCK
ADJUSTMENT LOCK TARGET
RS-232C/LAN
OSD DISPLAY
LED
TEMPERATURE ALERT
STATUS ALERT
POWER BUTTON
EXTERNAL CONTROLLER INPUT
SIGNAL RESPONSE LEVEL
OK:[ENTER] END:[RETURN]
2. Select and set the items.
ALL RESET
Resets the settings to the factory default settings.
Press the ENTER button, select the resetting method,
and then press the ENTER button.
After initialization, turn the main power switch off and
then back on.
ALL RESET1
....
Resets all the settings to the factory
default settings.
ALL RESET2
....
Returns all settings to the factory default
settings except for the following items:
LAN SETUP, RS-232C/LAN SELECT,
ID No. SET, REMOTE No., BAUD
RATE, NETWORK, MAIL, SERVICE &
SUPPORT, and SNMP (See page 29,
and pages 55 to 58.)
ADJUSTMENT LOCK
You can disable operations on the monitor and the
remote control unit that use buttons.
OFF ...Enables operation.
ON 1 ..Disables all operations other than turning power
on/off and FUNCTION.
ON 2 ..Only the FUNCTION operation is enabled.
Disables all operations other than FUNCTION (not
even power on/off).
ADJUSTMENT LOCK TARGET
Sets the target to prohibit operation of with
ADJUSTMENT LOCK.
REMOTE CONTROL
.....
Prohibits remote control
operation
MONITOR BUTTONS ... Prohibits monitor button
operation
BOTH
.............................
Prohibits remote control and
monitor button operation
RS-232C/LAN
Specifies whether to allow control via RS-232C or LAN
(see pages 38 and 51).
Initialization (Reset)/Functional Restriction Setting (FUNCTION)
OSD DISPLAY
Shows/hides the menu, modes and messages.
The FUNCTION and REMOTE CONTROL MODE
screens cannot be hidden.
ON 1
..............
Shows all menus, modes and messages.
ON 2
..............
Hides messages automatically displayed
by the display. Shows messages during
operation.
OFF
...............
Hides all menus, modes and messages.
LED
Specifies whether to light the power LED.
TEMPERATURE ALERT
Selects the notification method for an abnormal
temperature.
OFF
..............
Do not notify about an abnormal
temperature.
OSD & LED .. When an abnormal temperature is
detected, the power LED flashes in red
and green alternately and the screen
displays a message: TEMPERATURE.
LED
...............
When an abnormal temperature is
detected, the power LED flashes in red
and green alternately.
STATUS ALERT
Selects the notification method for a hardware error.
OFF
..............
Do not notify about the error.
OSD & LED .. When a hardware error is detected, the
power LED flashes in red and the screen
displays a message: STATUS [xxxx].
LED
...............
When a hardware error is detected, the
power LED flashes in red.
POWER BUTTON
Normally, leave this setting as MONITOR.
When using an optional part, if instruction appears,
change the setting accordingly.
EXTERNAL CONTROLLER INPUT
Normally, you do not need to change this setting.
When using an optional part, if instruction appears,
change the setting accordingly.
SIGNAL RESPONSE LEVEL
Normally, you do not need to change this setting. Use
this option to set the level of response to signal changes.
3. Press the RETURN button to return to the normal
screen.
TIPS
When both abnormal temperature and hardware error are
detected, the hardware error notification overrides.
If TEMPERATURE ALERT or STATUS ALERT is set to
OSD&LED, alert messages will appear even if the OSD
DISPLAY is set to ON 2 or OFF.
If TEMPERATURE ALERT or STATUS ALERT is set to LED
or OSD & LED, the LED lights even if the LED function is
set to OFF.