Sharp XG-C435X XG-C435X XG-C465X Operation Manual - Page 64

Resetting the Lamp Timer, Insert the new lamp unit., Replace the lamp unit cover.

Page 64 highlights

Regarding the Lamp 5 Insert the new lamp unit. • Press the lamp unit firmly into the lamp unit compartment. Fasten the securing screws. 6 Replace the lamp unit cover. • Align the lamp unit cover and slide it to close. Then tighten the user service screw to secure the lamp unit cover. Info • If the lamp unit and lamp unit cover are not correctly installed, the power will not turn on, even if the power cord is connected to the projector. Resetting the Lamp Timer Reset the lamp timer after replacing the lamp. Info • Make sure to reset the lamp timer only when replacing the lamp. If you reset the lamp timer and continue to use the same lamp, this may cause the lamp to become damaged or explode. • You can also reset the lamp timer via the LAN. (Refer to the SETUP MANUAL on the supplied CD-ROM for details.) 1 Connect the power cord. • Plug the power cord into the AC socket of the projector. 2 Reset the lamp timer. • While simultaneously holding down ", ENTER and MENU on the projector, press STANDBY/ON on the projector. • "LAMP 0000H" is displayed, indicating that the lamp timer is reset. -62 User service screw (for lamp unit cover) AC socket STANDBY/ON button ENTER button " button MENU button

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71

-62
5
Insert the new lamp unit.
Press the lamp unit firmly into the lamp
unit compartment. Fasten the securing
screws.
6
Replace the lamp unit cover.
Align the lamp unit cover and slide it to
close. Then tighten the user service
screw to secure the lamp unit cover.
Info
If the lamp unit and lamp unit cover are not
correctly installed, the power will not turn
on, even if the power cord is connected to
the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
Info
Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.
You can also reset the lamp timer via the
LAN.
(Refer to the SETUP MANUAL on the sup-
plied CD-ROM for details.)
1
Connect the power cord.
Plug the power cord into the AC socket
of the projector.
2
Reset the lamp timer.
While simultaneously holding down
"
,
ENTER and
MENU on the projector,
press
STANDBY/ON on the projector.
“LAMP 0000H” is displayed, indicating
that the lamp timer is reset.
User service screw
(for lamp unit cover)
AC socket
"
button
ENTER button
STANDBY/ON button
MENU button
Regarding the Lamp