Sony BRC-X400 Operating Instructions - Page 80

UPnP tab, CNS tab BRC-X400/X401, IPv4 QoS, Discovery, Camera network system

Page 80 highlights

IPv4 QoS Enable Select the checkbox to configure the QoS setting for IPv4. Rule Used to register, edit and delete QoS. No. Select the number to use when registering on the QoS table. When you select a registered number, the registered QoS information is displayed. Network address Enter the network address of the target on which to perform QoS. Subnet Enter the subnet mask values of the target on which to perform QoS. Tip The subnet mask value represents the number of bits from the left side of the network address. Protocol Select the protocol. Port Enter the port number for the data traffic of the device (e.g. HTTP: 80). DSCP Set a value to mark the data traffic (0 to 63). This value is set in the DSCP field included in the IP header of the data traffic. Set Used when registering on the QoS table. QoS is set according to the following procedure: 1 Select number for registration from [No.] and enter the necessary conditions for [Network address], [Subnet], [Protocol] and/or [Port]. 2 Enter values in [DSCP]. 3 Click [Set] and configure the QoS. Delete Select number from [No.] to delete the setting and click [Delete]. Move up Increases the priority of the rule. Select a rule from the QoS table to prioritize and click [Move up]. Move down Decreases the priority of the rule. Select a rule from the QoS table to lower its priority and click [Move down]. UPnP tab Set UPnP (Universal Plug and Play). Discovery Enable When this function is enabled, you can search the camera by using UPnP. Select the checkbox to use NDI|HX. CNS tab (BRC-X400/X401) The camera can be connected to an optional remote control panel (RCP) or master setup unit (MSU) for operation. For details about supported devices, contact your Sony sales representative. Configure the following settings on the CNS tab to connect with an RCP/MSU. Camera network system Mode [Bridge]: Set to Bridge mode to connect directly with an RCP on a LAN. [MCS]: Set to MCS mode when building a multi- camera system on a LAN. Master IP address Set the IP address of the master device when building a multi-camera system on a LAN. Camera No. Set the camera number when building a multicamera system on a LAN. Set so that the number is not duplicated within the system. Notes • Configure settings on the RCP/MSU side as required. • An MSU is required in a multi-camera system. • If there are multiple MSUs, set one MSU as the master, and set all other MSUs as clients. 80

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

80
IPv4 QoS
Enable
Select the checkbox to configure the QoS setting for
IPv4.
Rule
Used to register, edit and delete QoS.
No.
Select the number to use when registering on the
QoS table.
When you select a registered number, the registered
QoS information is displayed.
Network address
Enter the network address of the target on which to
perform QoS.
Subnet
Enter the subnet mask values of the target on which
to perform QoS.
Tip
The subnet mask value represents the number of
bits from the left side of the network address.
Protocol
Select the protocol.
Port
Enter the port number for the data traffic of the
device (e.g. HTTP: 80).
DSCP
Set a value to mark the data traffic (0 to 63).
This value is set in the DSCP field included in the IP
header of the data traffic.
Set
Used when registering on the QoS table.
QoS is set according to the following procedure:
1
Select number for registration from
[No.] and enter the necessary
conditions for [Network address],
[Subnet], [Protocol] and/or [Port].
2
Enter values in [DSCP].
3
Click [Set] and configure the QoS.
Delete
Select number from [No.] to delete the setting and
click [Delete].
Move up
Increases the priority of the rule.
Select a rule from the QoS table to prioritize and click
[Move up].
Move down
Decreases the priority of the rule.
Select a rule from the QoS table to lower its priority
and click [Move down].
UPnP tab
Set UPnP (Universal Plug and Play).
Discovery
Enable
When this function is enabled, you can search the
camera by using UPnP. Select the checkbox to use
NDI|HX.
CNS tab (BRC-X400/X401)
The camera can be connected to an optional
remote control panel (RCP) or master setup unit
(MSU) for operation. For details about supported
devices, contact your Sony sales representative.
Configure the following settings on the CNS tab
to connect with an RCP/MSU.
Camera network system
Mode
[Bridge]:
Set to Bridge mode to connect directly
with an RCP on a LAN.
[MCS]:
Set to MCS mode when building a multi-
camera system on a LAN.
Master IP address
Set the IP address of the master device when
building a multi-camera system on a LAN.
Camera No.
Set the camera number when building a multi-
camera system on a LAN. Set so that the number is
not duplicated within the system.
Notes
• Configure settings on the RCP/MSU side as
required.
• An MSU is required in a multi-camera system.
• If there are multiple MSUs, set one MSU as the
master, and set all other MSUs as clients.