Sony BRC-X400 Operating Instructions - Page 9

VISCA RS-422 OUT terminal, IR SELECT switch

Page 9 highlights

 VISCA RS-422 OUT terminal When you connect multiple cameras, connect it to the VISCA RS-422 IN terminal of the next camera in the daisy chain connection.  IR SELECT switch Select the camera number when you operate multiple cameras with the same remote commander.  Remote commander sensor This is for the supplied remote commander.  SYSTEM SELECT switch Used for selecting the video signal format to be output from the HDMI OUT and SDI OUT terminals. When the SYSTEM SELECT switch is set to 6, the value set on [VIDEO FORMAT] or [Format] under [Video out] on the Administrator menu is applied. For details, see "SYSTEM SELECT switch settings" (page 102).  Reset switch Press the switch for 5 seconds or longer to return to the factory default.   (earth) terminal  AC adapter cord clamper Fix the cord of an AC adapter with the cord clamper so that it does not come out.  MIC terminal (audio input terminal) Input for commercially-available MIC or LINE to connect an audio device. * Switch between MIC and LINE input, as indicated on "Connecting to commercially-available microphones etc." (page 25).  CAMERA SETUP switches Perform settings for the following 4 cameras. CAMERA SETUP switch settings ɟ ɠ ɞ ɡ Switch No. Setting items 1 Setting up 3G-SDI level 2 Termination setting of external synchronization 3 HTTP/RTSP communication usage setting 4 Baud Rate settings of RS-422 for VISCA communication  SDI format/level settings This setting is enabled when the signal format is 1920×1080/50p or 1920×1080/ 59.94p. When the SYSTEM SELECT switch is set to 6, the setting set on [VIDEO FORMAT] on the OSD menu or [Format] under [Video out] on the Administrator menu is applied. Switch state ON OFF SDI format/level Level-B Level-A * Turn the power off or to standby, then turn the power on to reflect the changes after setting.  Termination setting of external synchronization Use this setting during external synchronization (page 24). When you use the external synchronization while multiple cameras are connected, turn OFF when this camera is in the middle of a daisy chain connection and turn ON when this camera is at the end. When nothing is connected to the EXT SYNC terminal, turn ON. Switch state ON OFF TERMINATION TERMINATE OPEN * The setting is applied instantly.  HTTP/RTSP communication usage setting Use this setting when you set the HTTP/ RTSP protocol setting. Turn ON to forcibly enable the setting. Turn OFF to configure the setting according to the OSD menu. Switch state ON OFF HTTP/RTSP CONNECTION FORCED ON MENU * Turn the power off and on to reflect the changes after setting. 9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104

9
VISCA RS-422 OUT terminal
When you connect multiple cameras,
connect it to the VISCA RS-422 IN terminal of
the next camera in the daisy chain
connection.
IR SELECT switch
Select the camera number when you operate
multiple cameras with the same remote
commander.
Remote commander sensor
This is for the supplied remote commander.
SYSTEM SELECT switch
Used for selecting the video signal format to
be output from the HDMI OUT and SDI OUT
terminals. When the SYSTEM SELECT switch
is set to 6, the value set on [VIDEO FORMAT]
or [Format] under [Video out] on the
Administrator menu is applied.
For details, see “SYSTEM SELECT switch
settings” (page 102).
Reset switch
Press the switch for 5 seconds or longer to
return to the factory default.
(earth) terminal
AC adapter cord clamper
Fix the cord of an AC adapter with the cord
clamper so that it does not come out.
MIC terminal (audio input terminal)
Input for commercially-available MIC or LINE
to connect an audio device.
*
Switch between MIC and LINE input, as indicated
on “Connecting to commercially-available
microphones etc.” (page 25).
CAMERA SETUP switches
Perform settings for the following 4 cameras.
CAMERA SETUP switch settings
SDI format/level settings
This setting is enabled when the signal
format is 1920×1080/50p or 1920×1080/
59.94p.
When the SYSTEM SELECT switch is set to
6, the setting set on [VIDEO FORMAT] on
the OSD menu or [Format] under [Video
out] on the Administrator menu is
applied.
*
Turn the power off or to standby, then turn
the power on to reflect the changes after
setting.
Termination setting of external
synchronization
Use this setting during external
synchronization (page 24).
When you use the external
synchronization while multiple cameras
are connected, turn OFF when this
camera is in the middle of a daisy chain
connection and turn ON when this
camera is at the end.
When nothing is connected to the EXT
SYNC terminal, turn ON.
*
The setting is applied instantly.
HTTP/RTSP communication usage setting
Use this setting when you set the HTTP/
RTSP protocol setting.
Turn ON to forcibly enable the setting.
Turn OFF to configure the setting
according to the OSD menu.
*
Turn the power off and on to reflect the
changes after setting.
Switch No.
Setting items
1
Setting up 3G-SDI level
2
Termination setting of external
synchronization
3
HTTP/RTSP communication
usage setting
4
Baud Rate settings of RS-422
for VISCA communication
Switch state
SDI format/level
ON
Level-B
OFF
Level-A
Switch state
TERMINATION
ON
TERMINATE
OFF
OPEN
Switch state
HTTP/RTSP CONNECTION
ON
FORCED ON
OFF
MENU