TP-Link T1700X-16TS T1700X-16TSUN V1 User Guide - Page 236
Alarm Type, Interval, Owner, Status
View all TP-Link T1700X-16TS manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 236 highlights
Alarm Type: Interval: Owner: Status: Specify the type of the alarm. All: The alarm event will be triggered either the sampled value exceeds the Rising Threshold or is under the Falling Threshold. Rising: When the sampled value exceeds the Rising Threshold, an alarm event is triggered. Falling: When the sampled value is under the Falling Threshold, an alarm event is triggered. Enter the alarm interval time in seconds. Enter the name of the device or user that defined the entry. Enable/Disable the corresponding alarm entry. Note: When alarm variables exceed the Threshold on the same direction continuously for several times, an alarm event will only be generated on the first time, that is, the Rising Alarm and Falling Alarm are triggered alternately for that the alarm following to Rising Alarm is certainly a Falling Alarm and vice versa. Return to CONTENTS 225