Xerox 4400DT Service Manual - Page 440
Fuser Trouble (U4 Error Code), AC Power Shutoff to the Fuser, Fuser Temperature Cycling
![]() |
View all Xerox 4400DT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 440 highlights
Fuser Trouble (U4 Error Code) There are five major causes of a U4 error. I Warm-up failure - Fuser warm-up does not complete within specified seconds after starting. I Low Trouble temperature - The Fuser temperature drops to the Low Trouble temperature (approximately current control temperature, minus approximately 25° C. I High Trouble temperature - The Fuser temperature rises to the High Trouble temperature (approximately current control temperature, plus approximately 35° C. I Thermistor circuit opened. I STS failure - The Heat Rod remains on for at least ten seconds after warm-up has completed. AC Power Shutoff to the Fuser There are eight reasons that the printer shuts off AC power to the Fuser. I Fuser Failure (U4) I Paper jam I Open Front/Rear Cover Assembly I Laser failure (U2) I CPU or NVRAM problem (U6) I Main Motor Assembly problem (U1) I Fan problem (U5) I FUSER PAUSE command issued Fuser Temperature Cycling Fuser Temperature Cycling Temperature Name Temperature Value High Trouble Temperature Approximately 215° C (Standby temperature + approximately 35° C) Fuser Off Temperature Fuser control temperature +/- 0 ° C Fuser Control Temperature Standby temperature (180° C) Running temperature (195° C) Fuser On Temperature Fuser control temperature - 2° C Low Trouble Temperature Approximately 155° C (Standby temperature - approximately 25° C) Phaser 4400 Laser Printer Service Manual 8-27