Cisco 11503 Administration Guide - Page 239
Table 6-2, RMON Alarm Configuration Quick Start continued
UPC - 746320664958
View all Cisco 11503 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 239 highlights
Chapter 6 Configuring Remote Monitoring (RMON) Configuring an RMON Alarm Table 6-2 RMON Alarm Configuration Quick Start (continued) Steps and Possible Settings 7. Associate the rising event with an existing RMON event. Enter an integer from 0 to 65534. If you enter 0, no event is generated. (config-rmonalarm[1])# rising-event 1 8. Define the falling threshold. Enter an integer from 0 (default) to 4294967295. (config-rmonalarm[1])# falling-threshold 90 9. Associate the falling event with an existing RMON event. Enter a number from 0 to 65534. If you enter 0, no event is generated. (config-rmonalarm[1])# falling-event 2 10. Specify the sampling interval for the RMON alarm. The interval is in seconds. Enter an integer from 1 to 65535 (default is 300). (config-rmonalarm[1])# sample-interval 30 11. Activate the alarm. (config-rmonalarm[1])# active The following running-configuration example shows the results of entering the commands in Table 6-2. RMON ALARM rmon-alarm 1 owner "Boston Tech Lab" sample-variable apSvcConnections. sample-type absolute startup-type rising-and-falling rising-threshold 100 rising-event 1 falling-threshold 90 falling-event 2 sample-interval 30 active OL-5647-02 Cisco Content Services Switch Administration Guide 6-13