SCSI ID Configurations H-13 Single Bus Expansion Configuration Figure H-8 illustrates the proper location of the drives in the StorageWorks Enclosure Model 4214T (Tower) or Model 4214R (Rack). This external enclosure is seen as an extension of the internal shared storage and uses SCSI IDs 0-5, 8, and 15 to provide total support for 14 drives. The drives must be placed carefully in the external shared storage enclosure. Beginning at the bottom of a tower cabinet or on the left of a rack model, place drives consecutively in the first seven drive bays that are using SCSI IDs 0-5, 8. Then skip six bays because the SCSI IDs for these six bays are being used by the internal shared storage drives. Lastly, place one drive in the bay following the six bay gap, which should be located at the top of the tower model or far right in the rack model. SCSI IDs 15 14 N/A 13 N/A 12 N/A 11 N/A 10 N/A 9 N/A 8 8 7 5 6 4 5 3 4 2 3 1 2 0 1 Drive Bays Enclosure 4214 SCSI IDs Not Used 9 10 11 12 13 14 CR3500-1 CR3500-2 Server Node 1 Server Node 2 ProLiant CL380 Figure H-8. SCSI IDs for Single Bus Configuration