Gateway 9315 Gateway 9315 Server User Guide - Page 84
Important, Caution
View all Gateway 9315 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Important If you install two processors onto the system board, the processors must be the same speeds, revision, core voltage, and bus speed. 9 Install the new processor into the CPU socket, then press the processor locking lever down until it lays flat against the CPU socket. 10 Place the heat sink over the processor, lining up the four captive screws with the four posts surrounding the processor. Caution The heat sink has Thermal Interface Material (TIM) located on the bottom of it. Use caution when you unpack the heat sink so you do not damage the TIM. 11 Loosely screw in the captive screws on the corners of the heat sink, gently tightening diagonal screws (screw in one screw, then the screw located diagonally to the first screw). Do not fully tighten one screw before tightening another. 12 Gradually and equally tighten each captive screw until each is firmly tightened. Do not over-tighten the screws. 13 Follow the instructions in "Installing the processor air duct" on page 42. 14 Follow the instructions in "Closing the server case" on page 39. www.gateway.com 79