GE 60-806-95R-16Z Installation Instructions - Page 35

Phone Test Freq. 0302, Next Phone Test 0303, Output Trip Time 0304, Activity Timeout 0305, Daylight

Page 35 highlights

Phone Test Freq. (0302) Timers-Global (Default=7 days) This setting determines how often the panel sends the automatic phone test ¾ To set the Phone Test Freq: (see "Auto Phone Test" under PHONE OPTIONS-GLOBAL) to the central station 1. With the display showing PHONE TEST FREQ (or a pager). The phone test frequency can be set to report every 1 to 255 days. nnn DAYS (current setting), enter the number Note For UL 1635 listed installations, this feature must be set to 1. of days (1-255). The display flashes the entered setting. 2. Press ƒ and the display shows the new set- ting. Next Phone Test (0303) Timers-Global (Default=7 days) This setting determines how many days (1-255) until the next automatic phone test occurs. When setting up Phone Test Freq, Next Phone Test must be set to accurately count the number of days left in the cycle before the next phone test occurs. This setting should be the same or less than the Phone Test Freq. setting. Note For UL 1635 listed installations, this feature must be set to 1. ¾ To set the Next Phone Test: 1. With the display showing NEXT PHONE TEST nnn DAYS (current setting), enter the number of days (1-255). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. Output Trip Time (0304) Timers-Global (Default=4 sec.) This setting determines how long onboard and SnapCard outputs are activated when tripped (if they are configured for a momentary response). ¾ To set the Output Trip Time: 1. With the display showing OUTPUT TRIP TIME nn SECONDS (current setting), enter the number of seconds (1-12). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. Activity Timeout (0305) Timers-Global (Default=24 hours) This setting determines when the system sends a "no activity" report. The panel can be set to wait from 1-42 hours. If no user interaction or device activation occurs in that time, the panel sends a report to the central station. ¾ To set the Activity Timeout: 1. With the display showing ACTIVITY TIMEOUT nn HOURS (current setting) enter the desired 2-digit time value (1-42). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. Daylight Savings (0306) This setting determines whether or not the panel clock automatically adjusts for daylight saving time changes in spring and fall. Timers-Global (Default=on) ¾ To turn Daylight Savings off or on: 1. With the display showing DAYLIGHT SAVINGS OFF/ON (current setting), press 1 (off) or 2 (on). The display flashes the entered setting. 2. Press ƒ and the display shows the new setting. The following describes how to program the Timer settings that appear under PARTITION 1. Programming the Panel 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76

Programming the Panel
30
The following describes how to program the Timer settings that appear under
PARTITION 1
.
Phone Test Freq. (0302)
Timers-Global (Default=7 days)
This setting determines how often the panel sends the automatic phone test
(see “Auto Phone Test” under
PHONE OPTIONS—GLOBAL
) to the central station
(or a pager). The phone test frequency can be set to report every 1 to 255 days.
Note
For UL 1635 listed installations, this feature must be set to 1.
¾
To set the Phone Test Freq:
1.
With the display showing
PHONE TEST FREQ
nnn DAYS
(current setting)
, enter the number
of days (1-255). The display flashes the
entered setting.
2.
Press
ƒ
and the display shows the new set-
ting.
Next Phone Test (0303)
Timers-Global (Default=7 days)
This setting determines how many days (1-255) until the next automatic
phone test occurs. When setting up Phone Test Freq, Next Phone Test must be
set to accurately count the number of days left in the cycle before the next
phone test occurs. This setting should be the same or less than the Phone Test
Freq. setting.
Note
For UL 1635 listed installations, this feature must be set to 1.
¾
To set the Next Phone Test:
1.
With the display showing
NEXT PHONE TEST
nnn DAYS
(current setting)
, enter the number
of days (1-255). The display flashes the
entered setting.
2.
Press
ƒ
and the display shows the new set-
ting.
Output Trip Time (0304)
Timers-Global (Default=4 sec.)
This setting determines how long onboard and SnapCard outputs are activated
when tripped (if they are configured for a momentary response).
¾
To set the Output Trip Time:
1.
With the display showing
OUTPUT TRIP TIME
nn SECONDS
(current setting)
, enter the num-
ber of seconds (1-12). The display flashes
the entered setting.
2.
Press
ƒ
and the display shows the new set-
ting.
Activity Timeout (0305)
Timers-Global (Default=24 hours)
This setting determines when the system sends a “no activity” report. The
panel can be set to wait from 1-42 hours. If no user interaction or device acti-
vation occurs in that time, the panel sends a report to the central station.
¾
To set the Activity Timeout:
1.
With the display showing
ACTIVITY TIMEOUT
nn HOURS
(current setting)
enter the desired
2-digit time value (1-42). The display flashes
the entered setting.
2.
Press
ƒ
and the display shows the new set-
ting.
Daylight Savings (0306)
Timers-Global (Default=on)
This setting determines whether or not the panel clock automatically adjusts
for daylight saving time changes in spring and fall.
¾
To turn Daylight Savings off or on:
1.
With the display showing
DAYLIGHT SAV-
INGS OFF/ON
(current setting)
, press
1
(off)
or
2
(on). The display flashes the entered
setting.
2.
Press
ƒ
and the display shows the new set-
ting.