Specifications Power Requirements: .....Class II, 16.5 VAC, 25 VA, 60 Hz Rechargeable Batteries: ..12 VDC, 4Ah Lead-Acid (part no. 60-681) OR 12 VDC, 7Ah (part no. 60-680). The battery will last 24 hours with no AC and specified standby load Radio Frequency 319.5 MHz Nominal Range 750 feet (305 meters) typical open air Storage Temperature Range:- 30° to 140° F (-34° to 60° C) Operating Temperature Range: 32° to 120 ° F (0° to 49° C) Maximum Humidity: ......90% Relative Humidity (non-condensing) Auxiliary Power Output: 12 V @ 750 mA, current limited Dimensions 11 in. (28 cm) x 9 in. (23 cm) x 3.0 in. (7.6 cm) (H x W x D) Specifications 70
Specifications
70
Specifications
Power Requirements:
.....
Class II, 16.5 VAC, 25 VA, 60 Hz
Rechargeable Batteries:
..12 VDC, 4Ah Lead-Acid (part no. 60-681) OR 12 VDC, 7Ah (part no. 60-680).
The battery will last 24 hours with no AC and specified standby load
Radio Frequency:
............
319.5 MHz
Nominal Range:
...............
750 feet (305 meters) typical open air
Storage Temperature Range:-
30° to 140° F (-34° to 60° C)
Operating Temperature Range:
32° to 120 ° F (0° to 49° C)
Maximum Humidity:
......
90% Relative Humidity (non-condensing)
Auxiliary Power Output:
12 V @ 750 mA, current limited
Dimensions:
.....................
11 in. (28 cm) x 9 in. (23 cm) x 3.0 in. (7.6 cm) (H x W x D)