HP StorageWorks 6000 HP StorageWorks 6000-series Virtual Library System User G - Page 241
Hard Drive LED Combinations, Interpretation, Fault/UID LED, amber/blue, Online/activity, LED green
View all HP StorageWorks 6000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 241 highlights
Hard Drive LED Combinations Online/activity LED (green) Fault/UID LED (amber/blue) On, off, or flashing Alternating amber and blue On, off, or flashing Steadily blue On Amber, flashing regularly (1 Hz) Interpretation The drive has failed, or a predictive failure alert has been received for this drive; it also has been selected by a management application. The drive is operating normally, and it has been selected by a management application. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. On Off Flashing regularly (1 Hz) Amber, flashing regularly (1 Hz) The drive is online, but it is not active currently. Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is part of an array that is undergoing capacity expansion or stripe migration, but a predictive failure alert has been received for this drive. To minimize the risk of data loss, do not replace the drive until the expansion or migration is complete. Flashing regularly (1 Hz) Off Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding, or it is part of an array that is undergoing capacity expansion or stripe migration. Flashing irregularly Amber, flashing regularly (1 Hz) Flashing irregularly Off Off Steadily amber Off Amber, flashing regularly (1 Hz) Off Off The drive is active, but a predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is active, and it is operating normally. A critical fault condition has been identified for this drive, and the controller has placed it offline. Replace the drive as soon as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. HP StorageWorks 241