- HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 1
HP StorageWorks 8-Gb SAN Switch hardware reference manual Part number: 5697-8047 Third edition: June 2009 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 2
is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 3
Product warranties ...13 Subscription service ...13 HP websites ...14 Documentation feedback ...14 1 HP StorageWorks 8-Gb SAN Switches 15 Overview ...15 HP StorageWorks 8-Gb SAN Switch models 16 Power Pack+ models ...17 8/8 and 8/24 SAN Switch features 17 Port side of the 8/8 and 8/24 SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 4
Network Switch 56 8-Gb SAN Switch LEDs ...56 8/8 and 8/24 SAN Switch LEDs 57 8/40 SAN Switch LEDs ...57 8/80 SAN Switch LEDs ...58 Port side LED activity for the 8/80 SAN Switch 60 Nonport side LED activity for the 8/80 SAN Switch 62 Port side LED activity for the Encryption SAN Switch 63 Port - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 5
physical dimensions 83 Memory ...83 Facility requirements ...84 Electromagnetic compatibility (EMC 85 Power supply specifications ...85 Data transmission ranges ...87 FCoE Converged Network Switch data flow latency 90 Fibre Channel port specifications 90 POST and boot specifications ...90 POST - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 6
Italian notice ...100 Latvian notice ...101 Lithuanian notice ...101 Polish notice ...101 Portuguese notice ...102 Slovakian notice ...102 Slovenian notice ...102 Spanish notice ...102 Swedish notice ...103 B Electrostatic discharge 105 How to prevent electrostatic discharge 105 Grounding methods - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 7
-8/80 SAN Switch 22 6 Port side of the Encryption SAN Switch 24 7 Port side of the FCoE Converged Network Switch 25 8 Nonport side of the FCoE Converged Network Switch 26 9 Trunking groups example 27 10 8/40 SAN Switch shipping carton contents 32 11 Installing the rear mounting brackets (HP - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 8
33 Inserting the fan assembly in the 8/80 SAN Switch 76 34 Installing a power supply in the 8/80 or Encryption SAN Switch 77 35 Class 1 laser product label 94 8 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 9
83 20 8/8, 8/24 and 8/40 SAN Switch memory 84 21 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory ...84 22 Facility requirements 84 23 EMC compatibility 85 24 Power supply specifications 86 25 Laser data transmission ranges for the 8/8 and 8/24 SAN Switches 87 26 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 10
10 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 11
.hp.com/support/manuals In the Storage section, click Storage Networking. Then click the name of your switch (for example, HP StorageWorks 8/40 SAN Switch) to access the Manuals web page. The Fabric OS Encryption Administrator's Guide is only associated with the HP StorageWorks Encryption SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 12
conventions Convention Blue text: Table 1 Blue, underlined text: http://www.hp.com Bold text Element Cross-reference links and email addresses Website addresses or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. Rack stability - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 13
service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/go/e-updates After registering, you will receive email notification of product enhancements, new driver versions, firmware updates, and other product resources. 8-Gb SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 14
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 14 About this guide - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 15
Gb SAN Switches This chapter includes: • Overview, page 15 • HP StorageWorks 8Gb SAN Switch models, page 16 • Power Pack+ models, page 17 • 8/8 and 8/24 SAN Switch features, page 17 • 8/40 SAN Switch features, page 18 • 8/80 SAN Switch features, page 20 • Port side of the Encryption SAN Switch, page - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 16
8 active Fibre Channel ports, 24 active Converged Enhanced Ethernet (CEE) ports, base software (Full Fabric, Advanced Fabric OS, Advanced Web Tools, and Advanced Zoning), and Power Pack+ software (ISL Trunking, Advanced Performance Monitor, and Fabric Watch). 16 HP StorageWorks 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 17
, see the HP StorageWorks Fabric OS administrator guide for the firmware version you are running. 8/8 and 8/24 SAN Switch features • Functions as an edge device in fabrics of up to 239 switches. • Integrates a single motherboard design with 667 MHz PowerPC 440EPx Reduced Instruction Set Computer - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 18
as "Full Fabric License" and indicates that E_Ports are now automatically enabled. 8/40 SAN Switch features • Provides the EZSwitch Setup Wizard for easy setup and basic configuration. • Support for 1, 2, 4, and 8 Gb/s autosensing Fibre Channel switch and router ports. 18 HP StorageWorks 8-Gb SAN - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 19
6. Fibre Channel port status LED 7. Fibre Channel port Nonport side of the 8/40 SAN Switch The nonport side includes the two redundant power supply fan assemblies and the corresponding status LEDs. Figure 3 shows the nonport side of the 8/40 SAN Switch. 8-Gb SAN Switch hardware reference manual 19 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 20
(for power supply/fan FRU1) Figure 3 Nonport side view-8/40 SAN Switch Activating additional 8/40 SAN Switch ports By default, the 8/40 SAN Switch model integrates 24 licensed ports (ports 0 through 23). To enable additional ports, you must purchase and install the HP Storage Works 8/40 SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 21
8/80 SAN Switch. 1 8/80 SAN Switch 2 Switch ID pull-out tab 3 Status LED (top) power LED (bottom) 4 Console port 5 Ethernet port 6 USB port 7 FC ports 0-7 8 FC ports 8-15 9 FC ports 16-23 10 FC ports 24-31 11 FC ports 32-38 12 FC ports 40-47 13 FC ports 48-55 14 FC ports 56-63 15 FC ports 64-71 16 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 22
Fan assembly #1 7 Power supply #1 Activating additional 8/80 SAN Switch ports By default, the 8/80 SAN Switch model integrates 48 licensed ports (ports 0 through 47). To enable additional ports, you must purchase and install the HP StorageWorks 8/80 SAN Switch 8-Gb 16-port Upgrade LTU (part number - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 23
Gb/s Fibre Channel. Port side of the Encryption SAN Switch The port side of the Encryption SAN Switch includes the status and power LEDs, smart card reader, the RJ-45 USB, and Fibre Channel ports. Figure 6 shows the port side of the Encryption SAN Switch. 8-Gb SAN Switch hardware reference manual 23 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 24
• Contains 24 ports, 10-GbE CEE. • Provides Low-latency, lossless, deterministic interconnect required for FCoE. • Provides FCoE support with Fabric Provided MAC Address (FPMA) discovery. Fabric OS also enables support for Priority-based Flow Control (802.1Qbb). 24 HP StorageWorks 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 25
-GbE ports 16-23 4. Management Ethernet port 9. FC ports 0-7 5. USB port Figure 7 Port side of the FCoE Converged Network Switch Nonport side of the FCoE Converged Network Switch Figure 8 shows the nonport side of the FCoE Converged Network Switch. 8-Gb SAN Switch hardware reference manual 25 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 26
the portenable command, which enables the port laser. For example: portstart 16-31 6. Issue the portenable command to enable the ports. For example: portenable 16-31 7. Optional: Issue the portshow command to verify that the newly activated ports are started. 26 HP StorageWorks 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 27
0 through 7 2. Trunk group 2: Ports 8 through 15 3. Trunk group 3: Ports 16 though 23 Figure 9 Trunking groups example For more information about trunking, see the HP StorageWorks Fabric OS administrator guide for the firmware version you are running. 8-Gb SAN Switch hardware reference manual 27 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 28
Table 5 list the only SFPs supported in your HP StorageWorks 8-Gb SAN Switches. Table 2 FCoE Converged Network Switch long range and short range 10-Gb CEE and cable options Option HP 10-GbE SR B-series SFP+ Transceiver HP 10-GbE LR B-series SFP+ Transceiver HP 1m B-series Active Copper SFP+ Cable - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 29
kits Option Part number HP StorageWorks Full Fabric Upgrade License T4261A HP StorageWorks 8/8 and 8/24 SAN Switch 8-Gb 8-port Upgrade LTU T5518A HP StorageWorks 8/80 SAN Switch 8-Gb 16-port Upgrade LTU T5520A HP StorageWorks 8/40 SAN Switch 8-Gb 8-port Upgrade LTU T5519A Adaptive - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 30
221691-B23 221691-B26 221691-B27 NOTE: To obtain the latest information on hardware and software components, go to the B-Series section of the following HP website: http://www.hp.com/go/san. 30 HP StorageWorks 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 31
and configuring the SAN Switch, page 45 • Connecting the SAN Switch to the fabric, page 46 Shipping carton contents Figure 10 and Table 8 identify shipping carton contents for a typical 8-Gb SAN Switch. The shipping configuration for your model may vary. 8-Gb SAN Switch hardware reference manual 31 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 32
following items: • One set of HP StorageWorks product documentation, including HP Storage- Works 8-Gb SAN Switch quick start instructions, HP StorageWorks SAN Switch Rack Mount Kit installation instructions, Read Me First, Safety Guides, User License, and Warranty • One serial cable, approximately - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 33
and HP 10000 Series Rack See "Installing the switch using the SAN Switch Rack Mount Kit" on page 35 for detailed instructions. Electrical considerations For successful installation and operation of the switch, ensure that the following electrical requirements are met. See Power supply specifications - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 34
used in trunking groups must meet specific requirements, as described in the HP StorageWorks Fabric OS administrator guide. • For easier maintenance, label the fiber optic cables, and record the devices to which they are connected. • Keep LEDs visible by routing port cables and other cables away - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 35
than drawing in heated air from within the rack. A plenum ships with the following 8-Gb SAN Switch models only: • 8/8 SAN Switch • 8/24 SAN Switch See "Installing the plenum (if required)" on page 44 for complete instructions on how to install a plenum. 8-Gb SAN Switch hardware reference manual 35 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 36
a power strip. • Ensure that airflow and temperature requirements are met on an ongoing basis. • Secure the rack to ensure stability in case of unexpected movement. Installing the HP SAN Switch Rack Mount Kit in your HP custom rack The SAN Switch Rack Mount Kit enables you to install your HP device - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 37
The following items are required to install the switch in a rack: • SAN Switch • Power cables • #2 Phillips screwdriver • 7/16-inch wrench or socket • Plenum (if required). For 8-Gb models, a plenum is required for 8/8 and 8/24 SAN Switches only. • SAN Switch Rack Mount Kit hardware, shown in Table - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 38
CAUTION: For proper airflow, the SFP media side of the SAN Switch must face the rear of the rack. This mounting allows air to enter the front of the rack and exhaust are available. See Table 9. 2. Choose a mounting location for the device in the rack. 38 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 39
11 Installing the rear mounting brackets (HP 10000 series racks) Figure 12 Installing the rear mounting brackets (HP System/e Rack) NOTE: Your SAN Switch Rack Mount Kit contains both right rails and left rails. The rails are labelled Right and Left. 8-Gb SAN Switch hardware reference manual 39 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 40
and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 14. Figure 14 Assembling the outer rails (HP 10000 series racks) 40 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 41
rails to the switch Device model 8/8 SAN Switch 8/24 SAN Switch 8/40 SAN Switch 8/80 SAN Switch #8-32 x 5/16-inch #8-32 x 3/16-inch screws screws Ten (five per rail) N/A Encryption SAN Switch FCoE Converged Network Switch Six (three per rail) N/A 8-Gb SAN Switch hardware reference manual 41 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 42
to your specific device: a. To attach the inner rails to the 8/8 or 8/24 SAN Switches, use the five screw holes marked 8. The plenum requires one screw hole marked 8 and one screw hole marked 16, as shown in Figure 18 on page 44. b. To attach the inner rails to the 8/40 or 8/80 SAN Switches, use the - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 43
Figure 17 shows an inner rail attached to the 4/64 SAN Switch with five screws using the rail screw holes marked 16. Attaching both rails require ten screws. This figure also applies to the 8/8, 8/24, 8/40, and 8/80 SAN Switches. Figure 16 Securing the inner rails to an MP Router Figure 17 Securing - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 44
: Although Figure 18 illustrates how to attach the plenum to the 4/8 or 4/16 SAN Switch specifically, the procedure and figure also apply to installing the plenum on other models. 1. Plenum (installed) 2. 4/8 or 4/16 SAN Switch 3. Two screws that secure the rails to the plenum Figure 18 Attaching - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 45
Switch The SAN Switch must be configured to ensure correct operation with a network and fabric. For instructions on configuring the switch to operate in a fabric containing switches from other vendors, see the HP StorageWorks Fabric OS administrator guide. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 46
to back up the switch configuration (optional) Powering on the 8-Gb SAN Switch The 8/8 and 8/24 SAN Switches use one power cord. The 8/40 and 8/80 SAN Switches, Encryption SAN Switch, and FCoE Converged Network Switch use two power cords. IMPORTANT: The 8/8 and 8/24 SAN Switches do not have an - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 47
service loop of 6 inches, to avoid stress. The switch powers on automatically; there is no ON/OFF switch. To power off, remove the power cord from the power source. IMPORTANT: To protect against AC failure on the 8/40 and 8/80 SAN Switches, Encryption SAN Switch, and FCoE Converged Network Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 48
enabled by default. The 8-Gb SAN Switch supports both IPv4 and IPv6. DHCP When using DHCP, the 8-Gb SAN Switch obtains an IP address, subnet mask, and default 8-Gb SAN Switch, use a static IP address. Setting a static IP address 1. Log in to the switch using the default password, (password). 2. - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 49
for the Encryption SAN Switch). Setting the domain ID To set the switch domain ID: 1. Log on to the switch using Telnet, using the admin account. 2. Modify the domain ID, if required. The default domain ID is 1. • If the switch is not powered on until after it is connected to the fabric and the - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 50
--old option, see the Fabric OS Command Reference Manual. You can set the time zone for a switch using the tsTimeZone command. The tsTimeZone command allows you to perform the following tasks: • Display all of the time zones supported in the firmware. • Set the time zone based on a country and city - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 51
. For more information on using an NTP server, and IPv6 considerations, see the HP StorageWorks Fabric OS 6.1.x administrator guide and the HP StorageWorks Fabric OS 6.2.x administrator guide. 1. Log in to the switch using the default password: password. 8-Gb SAN Switch hardware reference manual 51 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 52
see Table 11. 2. Issue the switchshow command from the workstation. This command provides information about the switch and port status. 3. Issue the fabricshow command from the workstation. This command provides general information about the fabric. Backing up the configuration HP recommends regular - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 53
The command uploads the switch configuration to the server, making it available for downloading to a replacement switch, if necessary. For detailed instructions on backing up the configuration, see the HP StorageWorks Fabric OS administrator guide. 8-Gb SAN Switch hardware reference manual 53 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 54
54 Installing and configuring an 8-Gb SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 55
the HP StorageWorks 8/40 and 8/80 SAN Switches, the Encryption SAN Switch and the FCoE Converged Network Switch. This chapter describes the following topics: • Configuring the Encryption SAN Switch, page 55 • Interpreting LED activity, page 56 • Port side LED activity for the 8/80 SAN Switch, page - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 56
Figure 22 Encryption configuration Configuring the FCoE Converged Network Switch See the Brocade Converged Enhanced Ethernet Administrator's Guide for details on configuring the CEE portion of the FCoE Converged Network Switch. 8-Gb SAN Switch LEDs System activity and status can be determined - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 57
8/24 SAN Switch LEDs are located on the port side only. 1 System power LED (green) 2 System status LED (green/amber) 3 Link status LED 4 Link speed LED 5 Port status LED (port 3) 6 Port status LED (port 7) Figure 23 Identifying 8/8 and 8/24 SAN Switch LEDs 8/40 SAN Switch LEDs 8/40 SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 58
LEDs (green/amber) 3 FC port status (port 9) Figure 24 Identifying 8/40 SAN Switch port side LEDs 1 Power supply 1 status LED 2 Power supply 2 status LED Figure 25 Identifying 8/40 SAN Switch nonport side LEDs 8/80 SAN Switch LEDs 8/80 SAN Switch LEDs are located on the port side and nonport side - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 59
LED (port 0) 7 FC port status LED (port 4) 8 FC ports (0 through 7) 9 FC ports (48 through 55) 10 FC port status LED (port 52) 11 FC port status LED (port 48) 12 Console port 13 System power LED Figure 26 Identifying 8/80 SAN Switch port side LEDs 8-Gb SAN Switch hardware reference manual 59 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 60
LED Figure 27 Identifying 8/80 SAN Switch nonport side LEDs Port side LED activity for the 8/80 SAN Switch Table 11 describes LEDs and recommended actions. Table 11 8-Gb SAN Switch port side LED patterns LED name LED color Status of hardware Recommended action Power status No light Steady - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 61
running. Re-enable the port using the portEnable command. Fast flashing amber (flashing in halfsecond intervals) Port is faulty. Check the management interface and the error log for details on the cause of status. Contact your switch service provider. 8-Gb SAN Switch hardware reference manual 61 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 62
has failed. • The fan FRU was disabled by the user. NOTE: When the switch is first powered on, the fan status LED will show amber until POST has completed. Try the following: • Verify the fan FRU is enabled (use the fanEnable command). • Replace the fan FRU. 62 Managing the 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 63
: • Verify the power LED is on; check the SFP and cable. • Verify the switch is initializing. • Verify the status of the connected device. Steady green Port is online (connected to external device), but there is no traffic. No action required. 8-Gb SAN Switch hardware reference manual 63 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 64
not running. Re-enable the port us- command. ing the portEnable command. Fast flashing amber (on 1/2 second, SFP or port is faulty. then off 1/2 second) Replace the SFP. Reset the port. No light Indicates one of the following: • Power supply FRU is switched off. • Power supply FRU is not - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 65
power LED 2. System status LED 3. Ethernet speed LED 4. Ethernet link LED 5. CEE port status LED (port 0) 6. CEE port status LED (port 4) Figure 28 Port side LEDs on the FCoE Converged Network Switch Table 14 describes the port side LEDs and the recommended actions. 8-Gb SAN Switch hardware - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 66
power supply failure, fan failure, or if one or more environmental ranges have been exceeded. Check the management interface and the error log for details on the cause of the status. Contact your switch service provider. Port , but not online No action required. 66 Managing the 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 67
supply and fan assembly locations. 1. Power supply #2 status LED 2. Power supply #1 status LED 3. Fan assembly #3 status LED 4. Fan assembly #2 status LED 5. Fan assembly #1 status LED Figure 29 Nonport side LEDs on the FCoE Converged Network Switch 8-Gb SAN Switch hardware reference manual 67 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 68
fan FRU. Interpreting POST results POST is a system check that is performed each time the switch is powered on, rebooted, or reset, and during which the LEDs flash different colors. To determine if POST completed successfully and whether any errors were detected: 68 Managing the 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 69
how to turn beaconing on and off, see the HP StorageWorks Fabric OS administrator guide or the Web Tools administrator's guide. b. Follow the recommended action for the observed LED behavior, as listed in Table 11 and Table 12. 2. Verify that the switch prompt displays on the terminal of a computer - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 70
about specific diagnostic tests, see the Brocade Fabric OS Troubleshooting and Diagnostics Guide. Installing Field-Replaceable Units This section lists FRUs and provides FRU installation procedures. 8/8 SAN Switch and 8/24 SAN Switch FRU units No components in the 8/8 SAN Switch and 8/24 SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 71
display fan status as shown below: switch:admin> fanshow Fan 1 is OK, speed is 9507 RPM Fan 2 is OK, speed is 9246 RPM Fan 3 is OK, speed is Figure 31 Nonport side LEDs 1. Status LED for power supply/fan unit 2 2. Status LED for power supply/fan unit 1 8-Gb SAN Switch hardware reference manual 71 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 72
FRU is enabled and the FRU is faulty it should be replaced. Replacing the 8/40 SAN Switch power supply and fan assembly CAUTION: Disassembling any part of the power supply and fan assembly voids the warranty and regulatory certifications. There are no user-serviceable parts inside the power supply - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 73
FRUs as required: • Fan assembly • Power supply The 8/80 SAN Switch and Encryption SAN Switch integrate three fan assemblies (see Figure 32). Fabric OS identifies the fans from left to right as Fan assembly #3, Fan assembly #2, and Fan assembly #1. 8-Gb SAN Switch hardware reference manual 73 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 74
Fan assembly #2 5. Fan assembly #3 Figure 32 8/80 and Encryption SAN Switch fan assemblies on the nonport side CAUTION: Disassembling any part of the fan assembly voids the part warranty and regulatory certifications. There are no user-serviceable parts inside the fan assembly. Because the cooling - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 75
CAUTION: The 8/80 and Encryption SAN Switches use two power cords. Disconnect both power cords before servicing. To replace a fan assembly: 1. Use a Phillips-head screwdriver to unscrew the captive screw on the fan assembly you are replacing. 2. Remove the fan assembly from - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 76
33 Inserting the fan assembly in the 8/80 SAN Switch Replacing an 8/80 SAN Switch or Encryption SAN Switch power supply CAUTION: If a power supply fails, leave the power supply in the switch until it can be replaced. Maintain both power supplies in operational condition to provide redundancy - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 77
powered off, press the AC power switch to power it off. 3. Unplug the power cord from the power supply you are replacing. 1. AC power receptacle 3. Handle 5. AC power switch 2. Status LED 4. Captive screw 6. Power supply Figure 34 Installing a power supply in the 8/80 or Encryption SAN Switch - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 78
monitor fabric topology, check port status, and debug the switch. Table 17 lists the management tools available. When running IP over FC, these management tools must be supported by both HBA and HBA drivers. For a list of supported HBAs, see the HP StorageWorks SAN design guide: http://www.hp.com - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 79
(over HBA only Data Center Fabric Manager (optional)-For information, see the Brocade Data Center Fabric Manager Enterprise User guide or the Brocade Data Center Fabric Manager Professional User guide. Ethernet or serial connection IP over FC 8-Gb SAN Switch hardware reference manual 79 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 80
80 Managing the 8-Gb SAN Switches - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 81
for the Encryption SAN Switch. Table 18 Encryption SAN Switch general specifications Specification Fibre Channel ports Ethernet ports Smart cards Compression for tape Encryption Description 32 FC ports universal (E, F, EX, FL, and M) Two 1000 Base Ethernet ports for I/O synchronization during - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 82
, NPIV, FDML, Management Server, FSPF, Fabric Watch, Extended Fabrics, ISL, Trunking, Advanced Performance Monitor (APM), Adaptive Networking, Per data flow QoS, Ingress port rate limiting, Traffic Isolation, Group Management, Integrated Routing, and IPFC. 82 Encryption SAN Switch specifications - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 83
87 • Fibre Channel port specifications, page 90 • POST and boot specifications, page 90 • Supported HBAs, page 91 Weight and physical dimensions Table 19 lists physical properties for the SAN Switches. Table 19 8-Gb SAN Switch physical dimensions Property Height 8/8 and 8/24 SAN Switches 4.29 cm - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 84
8/24 and 8/40 SAN Switch memory Memory type Main Memory (SDRAM) Boot Flash Compact Flash Install memory 512 MB 8/40 SAN Switch only: 4 MB 1 GB Table 21 lists 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory specifications. Table 21 8/80 SAN Switch, Encryption SAN - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 85
8/24, and 8/40 SAN Switches and FCoE Converged Network Switch-One rack unit in a 48.3 cm (19 in) cabinet. 8/80 and Encryption SAN Switches- power supply integrates its own built-in fan for cooling, pushing the air forward toward the port side of the switch. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 86
044.11 BTU/hr 8/8 and 8/24 SAN Switches: 21.5 A at 240 VAC cold start 8/40 SAN Switch: 15-35 A maximum 8/80 SAN Switch: 15 A maximum for period of 10-150 mS Encryption SAN Switch: Less than 60 A peak FCoE Converged Network Switch: Maximum of 60 A for period of 10-150 ms 86 Technical Specifications - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 87
40 SAN Switch, up to 500 km at 1 Gb is supported when using a long distance transport system such as DWDM. Table 26 Laser data transmission ranges for the 8/40 SAN Switch Port km (6.2 miles) Extended long wavelength N/A N/A 40 km (24.8 miles) N/A N/A 8-Gb SAN Switch hardware reference manual 87 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 88
an HP Extended Fabrics license 40 km (24.8 miles) N/A N/A N/A N/A N/A 10 km N/A N/A N/A N/A N/A N/A NOTE: For the 8/80 SAN Switch, up to 500 km at 1 Gb is supported when using a long distance transport system such as DWDM. Table 27 Laser data transmission ranges for the 8/80 SAN Switch Port - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 89
Table 28 Laser data transmission ranges for the Encryption SAN Switch and the FCoE Converged Network Switch Port speed 1 Gb/s 2 Gb/s Cable size ( ) NOTE: Up to 500 km at 1 Gb/s is supported when using a long distance transport system such as DWDM. 8-Gb SAN Switch hardware reference manual 89 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 90
flow Size in nanolatency Type seconds FC port to FC port +/- 700 ns CEE port to CEE port (same ASIC) 570 ns CEE port to CEE port (different ASIC) 91,050 ns FCoE to FC 1,670 ns Fibre Channel port specifications The Fibre Channel ports in the 8-Gb SAN Switch are compatible with SWL, LWL, and - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 91
. • Enables normal port operation. Supported HBAs and CNAs NOTE: Converged Network Adapters (CNAs) apply to the FCoE Converged Network Switch only. For a list of HBAs that have been tested and are known to work with the SAN switches, refer to the latest version of the HP StorageWorks SAN design - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 92
92 Technical Specifications - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 93
International Electrotechnical Commission (IEC) 825. With specific regard to the laser, the equipment complies with laser product performance standards set by government agencies as a Class 1 laser product. The product does not emit hazardous light. 8-Gb SAN Switch hardware reference manual 93 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 94
HP authorized service technicians to repair the laser device. Certification and classification information This product contains a laser internal to the fiber optic (FO) transceiver for connection to the Fibre Channel communications port -1:1994, including Amendment 11:1996 and Amendment 2:2001. - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 95
numérique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. European Union regulatory notice BSMI notice 8-Gb SAN Switch hardware reference manual 95 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 96
Your switch is equipped with a lithium manganese dioxide, a vanadium pentoxide, or an alkaline internal battery or battery pack. There is a danger of explosion and risk of personal injury if the battery is incorrectly replaced or mistreated. Replacement is to be done by an HP authorized service - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 97
or water. • Replace only with the HP spare part designated for this product. Batteries, battery packs, and accumulators should not be disposed of If you have questions about the type of power cord to use, contact an HP authorized service provider. 8-Gb SAN Switch hardware reference manual 97 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 98
and the point where the cords exit from the product. Japanese power cord statement Waste Electrical and Electronic Equipment directive English notice Disposal of , please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Dutch notice - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 99
éservation des ressources naturelles et garantit que ces appareils seront recyclés dans le respect de la santé humaine et de l'environnement. Pour obtenir plus 8-Gb SAN Switch hardware reference manual 99 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 100
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German notice Entsorgung von Altgeräten aus privaten - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 101
, contattare l'ente locale per lo smaltimento dei rifiuti, oppure il negozio presso il quale è stato acquistato il prodotto. Latvian notice Lithuanian notice Polish notice 8-Gb SAN Switch hardware reference manual 101 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 102
ambiente e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian notice Slovenian notice Spanish notice Eliminaci - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 103
lokala kommunkontor, din närmsta återvinningsstation för hushållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. 8-Gb SAN Switch hardware reference manual 103 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 104
104 Regulatory compliance and safety - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 105
Use conductive field service tools. • Use a portable field service kit with a folding HP authorized reseller install the part. NOTE: For more information on static electricity, or for assistance with product installation, contact your HP authorized reseller. 8-Gb SAN Switch hardware reference manual - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 106
106 Electrostatic discharge - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 107
, 12 related documentation, 11 documentation HP website, 11 providing feedback, 14 domain ID setting, 49 E electrical considerations, 33 electromagnetic compatibility, 85 Encryption SAN switch nonport side of, 21 environmental considerations, 33 8-Gb SAN Switch hardware reference manual 107 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 108
, 13 HP technical support, 13 HP StorageWorks SAN switches 8/40 power pack+, 16 8/80 power pack+, 16 HP StorageWorks SAN switches encryption power pack+, 16 HP StorageWorks SAN switches 8/24, 16 8/40, 16 8/8 base, 16 8/8 full fabric, 16 8/80, 16 encryption, 16 FCoE converged network, 16 power pack - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 109
installing, 69 SFP transceiver options supported, 28 shipping carton contents, 31 specifications facility requirements, 84 Fibre Channel port, 90 memory, 83 physical, 83 POST and boot, 90 power supply, 85 Subscriber's Choice, HP, 13 supported sfp options, 28 supported HBAs, 91 switchshow command, 52 - HP StorageWorks 8/80 | HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 110