HP StorageWorks 8/80 HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 26

Installing and activating Port Upgrade licenses

Page 26 highlights

1. Power supply #2 2. Fan assembly #3 3. Fan assembly #2 4. Fan assembly #1 5. Power supply #1 Figure 8 Nonport side of the FCoE Converged Network Switch Installing and activating Port Upgrade licenses 1. Use the portshow command to verify the number of ports licensed on your switch. The port status output indicates Started and Licensed for enabled ports. See the Fabric OS Command Reference Manual for specific information on this command. 2. Obtain the WWN from the Switch ID pull-out tab located on the port side of your switch. Or you can use the switchshow command to display the WWN. 3. Contact your HP representative to purchase the appropriate Port Upgrade license. HP requires the switch WWN obtained in Step 2 to assign a license key. 4. Install the license: a. Log in to the switch as admin. b. Issue the licenseadd command, followed by the license key enclosed in quotation marks. (The license key consists of approximately 16 uppercase and lowercase letters and numerals.) NOTE: Enter the license key exactly as issued. If you enter the key incorrectly, the license will not function properly. c. Issue the licenseshow command to verify that the license is valid. If a licensed product is not displayed, the license is invalid. NOTE: It is not necessary to reboot the system. 5. Configure the inactive ports. Issue the portstart command to start the ports. This command loads the port code, unlike the portenable command, which enables the port laser. For example: portstart 16-31 6. Issue the portenable command to enable the ports. For example: portenable 16-31 7. Optional: Issue the portshow command to verify that the newly activated ports are started. 26 HP StorageWorks 8-Gb SAN Switches

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

4. Fan assembly #1
1. Power supply #2
5. Power supply #1
2. Fan assembly #3
3. Fan assembly #2
Figure 8 Nonport side of the FCoE Converged Network Switch
Installing and activating Port Upgrade licenses
1.
Use the
portshow
command to verify the number of ports licensed on your switch. The port
status output indicates
Started
and
Licensed
for enabled ports. See the
Fabric OS Command
Reference Manual
for specific information on this command.
2.
Obtain the WWN from the Switch ID pull-out tab located on the port side of your switch. Or you
can use the
switchshow
command to display the WWN.
3.
Contact your HP representative to purchase the appropriate Port Upgrade license. HP requires
the switch WWN obtained in
Step 2
to assign a license key.
4.
Install the license:
a.
Log in to the switch as
admin
.
b.
Issue the
licenseadd
command, followed by the license key enclosed in quotation marks.
(The license key consists of approximately 16 uppercase and lowercase letters and numerals.)
NOTE:
Enter the license key exactly as issued. If you enter the key incorrectly, the license will
not function properly.
c.
Issue the
licenseshow
command to verify that the license is valid. If a licensed product is
not displayed, the license is invalid.
NOTE:
It is not necessary to reboot the system.
5.
Configure the inactive ports. Issue the
portstart
command to start the ports. This command
loads the port code, unlike the
portenable
command, which enables the port laser. For example:
portstart 16
31
6.
Issue the
portenable
command to enable the ports. For example:
portenable 16
31
7.
Optional:
Issue the
portshow
command to verify that the newly activated ports are started.
HP StorageWorks 8-Gb SAN Switches
26