HP StorageWorks 8/80 HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 65
Port side LED activity for the FCoE Converged Network Switch
View all HP StorageWorks 8/80 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 65 highlights
Fan status No light Steady green Steady amber (for more than 5 seconds) Indicates one of the following: • Fan FRU is not seated correctly. • Fan FRU is not receiving power. Try one of the following: • Verify that the fan FRU is seated correctly. • Verify that the switch is powered on. Fan assembly I operating normally. No action required. Indicates one of the following: • Fan FRU is not seated correctly. • One or more of the fans in the fan FRU has failed. • The fan FRU was disabled by the user. NOTE: When the switch is first powered on, the fan status LED shows amber until POST has completed. Try one of the following: • Verify that the fan FRU is seated correctly. • Verify that the fan FRU is enabled (use the fanEnable command). • Replace the fan FRU. Port side LED activity for the FCoE Converged Network Switch Figure 28 shows the port side of the FCoE Converged Network Switch. There are two port status LEDs above each of the top row of ports. The left LED is for the top port; while the right LED is for the bottom port. See Figure 7 on page 25 for the locations of the GbE and FC ports. 1. System power LED 2. System status LED 3. Ethernet speed LED 4. Ethernet link LED 5. CEE port status LED (port 0) 6. CEE port status LED (port 4) Figure 28 Port side LEDs on the FCoE Converged Network Switch Table 14 describes the port side LEDs and the recommended actions. 8-Gb SAN Switch hardware reference manual 65