HP StorageWorks 8/80 HP StorageWorks 8-Gb SAN Switch hardware reference manual - Page 84

Facility requirements, Table 21 8/80 SAN Switch, Encryption SAN Switch

Page 84 highlights

Table 20 8/8, 8/24 and 8/40 SAN Switch memory Memory type Main Memory (SDRAM) Boot Flash Compact Flash Install memory 512 MB 8/40 SAN Switch only: 4 MB 1 GB Table 21 lists 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory specifications. Table 21 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory Memory type Install memory Main Memory (DDR2 SDRAM) Boot Flash Compact Flash 1 GB 4 MB 1 GB Facility requirements To ensure correct operation, the facility where the switch is in use must meet the requirements shown in Table 22. Table 22 Facility requirements Type Electrical Requirements 8/8, 8/24, 8/80, and Encryption SAN Switches-Primary AC input: 100-240 VAC, 2.0 A, 47-63 Hz; switch autosenses input voltage. 8/40 SAN Switch-Primary AC input: 90-264 VAC; switch autosenses input voltage. FCoE Converged Network Switch-Primary AC input: 85-264 VAC; input line frequency 47-63 Hz. Adequate supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate. Circuit protected by a circuit breaker and grounded in accordance with local electrical codes. Electrical interference less than the levels in the standards listed in Table 23. Thermal 8/8 and 8/24 SAN Switches-A minimum of 24 cu ft/min of airflow is available to the air intake vents on the nonport side of the switch. 8/40, 8/80, and Encryption SAN Switches-Air flows from the nonport side to the port side. A minimum airflow of 47 cu ft/min (79.8 cu m/hr) is available in the immediate vicinity of the switch. Ambient air temperature not to exceed 40ºC (104ºF) while the switch is operating. FCoE Converged Network Switch-Air flows from the nonport side to the port side. A maximum airflow of 42 cu ft/min (71.36 cu m/h) nominal airflow of 35 cu ft/min (59.47 cu m/h). 84 Technical Specifications

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

Table 20 8/8, 8/24 and 8/40 SAN Switch memory
Install memory
Memory type
512 MB
Main Memory (SDRAM)
8/40 SAN Switch only: 4 MB
Boot Flash
1 GB
Compact Flash
Table 21
lists 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch
memory specifications.
Table 21 8/80 SAN Switch, Encryption SAN Switch, and FCoE Converged Network Switch memory
Install memory
Memory type
1 GB
Main Memory (DDR2 SDRAM)
4 MB
Boot Flash
1 GB
Compact Flash
Facility requirements
To ensure correct operation, the facility where the switch is in use must meet the requirements shown
in
Table 22
.
Table 22 Facility requirements
Requirements
Type
8/8, 8/24, 8/80, and Encryption SAN Switches
Primary AC input: 100
240 VAC,
2.0 A, 47
63 Hz; switch autosenses input voltage.
8/40 SAN Switch
Primary AC input: 90
264 VAC; switch autosenses input voltage.
FCoE Converged Network Switch
Primary AC input: 85
264 VAC; input line
frequency 47
63 Hz.
Adequate supply circuit, line fusing, and wire size, as specified by the electrical
rating on the switch nameplate.
Circuit protected by a circuit breaker and grounded in accordance with local
electrical codes.
Electrical interference less than the levels in the standards listed in
Table 23
.
Electrical
8/8 and 8/24 SAN Switches
A minimum of 24 cu ft/min of airflow is available
to the air intake vents on the nonport side of the switch.
8/40, 8/80, and Encryption SAN Switches
Air flows from the nonport side to the
port side. A minimum airflow of 47 cu ft/min (79.8 cu m/hr) is available in the
immediate vicinity of the switch.
Ambient air temperature not to exceed 40ºC (104ºF) while the switch is operating.
FCoE Converged Network Switch
Air flows from the nonport side to the port side.
A maximum airflow of 42 cu ft/min (71.36 cu m/h) nominal airflow of 35 cu ft/min
(59.47 cu m/h).
Thermal
Technical Specifications