Troubleshooting CReplacing the Master Roll When C lights, it is time to replace the master roll. It also lights when the master roll is not set properly. Important ❒ Faults may occur if you use the master roll other than the recommended type. Note ❒ When the Master End indicator is lit, it is necessary to replace the master roll even if some master remains on the old roll. • 1: Pull out the master tray until it stops. 4 ACY040S • 2: Push the button. • 3: Open the master guide. AJK304S • 4: Open the master tray cover. • 5: Remove the used master roll. ACY042S 130 ACY043S • 6: The new master roll must be positioned as shown in the illustration. • 7: Close the master tray cover.
Troubleshooting
130
4
C
Replacing the Master Roll
When
C
lights, it is time to replace the master roll. It also lights when the master
roll is not set properly.
Important
❒
Faults may occur if you use the master roll other than the recommended type.
Note
❒
When the
Master End
indicator is lit, it is necessary to replace the master roll
even if some master remains on the old roll.
•
1: Pull out the master tray until it stops.
•
2: Push the button.
•
3: Open the master guide.
•
4: Open the master tray cover.
•
5: Remove the used master roll.
•
6: The new master roll must be positioned
as shown in the illustration.
•
7: Close the master tray cover.
ACY040S
AJK304S
ACY042S