Xerox 6180N Generic MICR Fundamentals Guide - Page 94
Use the MICR Gauge to measure character-to-character vertical
UPC - 095205425307
View all Xerox 6180N manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 94 highlights
Quality control The bottom edges of adjacent characters within each field should not vary vertically by more than 0.030 inch/0.75 mm (ANSI), 0.015 inch/0.381 mm (ISO), and 0.007 inch/0.18 mm (CPA). Vertical variation occurs most often in the Amount field, which indicates an impact printer problem. Use the MICR Gauge to measure character-to-character vertical position (see the following figure). Vertical variation from one character to the next is seldom produced by a Xerox MICR printing system unless the document has design problems. Vertical character alignment section Note the closer tolerance for Canadian and International standards Align bottom of MICR characters on the document with center solid line Vertical character alignment section enlarged Figure 6-5. Vertical variation check using the MICR gauge 6-8 Generic MICR Fundamentals Guide