Yamaha PSR-S900 Owner's Manual - Page 139

Saving the Registration Sequence Settings, the REGISTRATION BANK Selection display.

Page 139 highlights

Recalling the Registered Panel Setups 4 Use the [E] button to determine how Registration Sequence behaves when reaching the end of the sequence (SEQUENCE END). STOP Pressing the TAB [®] button or the "advance" pedal has no effect. The sequence is "stopped." TOP The sequence starts again at the beginning. NEXT BANK...........The sequence automatically moves to the beginning of the next Registration Memory Bank in the same folder. 5 Program the Sequence order. The numbers shown at the lower part of the display correspond to the REG- ISTRATION MEMORY [1]-[8] buttons on the panel. Program the Sequence order from left to right. Press one of the REGISTRATION MEMORY [1]-[8] button on the panel, then press the [6π†] (INSERT) button to input the number. • Replacing the number Press the [5π†] (REPLACE) button to replace the number at the cursor position with the currently selected Registration Memory number. • Deleting the number Press the [7π†] (DELETE) button to delete the number at the cursor position. • Deleting all numbers Press the [8π†] (CLEAR) button to delete all numbers in the sequence. 6 Press the [F] button to turn the Registration Sequence function on. 7 Press the [DIRECT ACCESS] button, then the [EXIT] button to return to CAUTION Settings in the REGISTRATION the Main display and confirm whether the Registration Memory numbers are called up according to the sequence programmed above. • Use the TAB [®] button to call up the Registration Memory numbers in the order of the sequence, or use the TAB [√] button to call them up in SEQUENCE display are automatically saved to the instrument when you exit from this display. However, if you turn the power off without exiting reverse order. The TAB [√][®] buttons can only be used for Registration Sequence when the Main display is called up. from this display, the settings will be lost. • When pedal operation has been set in step 3, you can use a pedal to select Returning to the first the Registration Memory numbers in order. The pedal can be used for Reg- Sequence in one action istration Sequence no matter which display is called up (except for the dis- In the Main display, press the play in step 3). TAB [√] and [®] buttons simultaneously. This cancels the cur- rently selected Sequence number (the box indicator at the top right goes out). The first Sequence will be selected by The Registration Sequence is indicated at the top pressing one of the TAB [√][®] right of the Main display, letting you confirm the buttons or by pressing the pedal. currently selected number. Saving the Registration Sequence Settings The settings for the Sequence order and how Registration Sequence behaves when reaching the end of the sequence (SEQUENCE END) are included as part of the Registration Memory Bank file. To store your newly programmed Registration Sequence, save the current Registration Memory Bank file. 1 Press the REGIST BANK [+] and [-] buttons simultaneously to call up the REGISTRATION BANK Selection display. 2 Press the [6†] button to save the Bank file (page 73). CAUTION Keep in mind that all Registration Sequence data is lost when changing Registration Memory Banks, unless you've saved it with the Registration Memory Bank file. Registering and Recalling Custom Panel Setups PSR-S900/S700 Owner's Manual 139

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224

Recalling the Registered Panel Setups
PSR-S900/S700 Owner’s Manual
139
Registering and Recalling Custom Panel Setups
4
Use the [E] button to determine how Registration Sequence behaves
when reaching the end of the sequence (SEQUENCE END).
STOP
.....................
Pressing the TAB [
®
] button or the “advance” pedal has
no effect. The sequence is “stopped.”
TOP
.......................
The sequence starts again at the beginning.
NEXT BANK
...........
The sequence automatically moves to the beginning of
the next Registration Memory Bank in the same folder.
5
Program the Sequence order.
The numbers shown at the lower part of the display correspond to the REG-
ISTRATION MEMORY [1]–[8] buttons on the panel.
Program the Sequence order from left to right.
Press one of the REGISTRATION MEMORY [1]–[8] button on the
panel, then press the [6
π†
] (INSERT) button to input the number.
• Replacing the number
Press the [5
π†
] (REPLACE) button to replace the number at the cursor
position with the currently selected Registration Memory number.
• Deleting the number
Press the [7
π†
] (DELETE) button to delete the number at the cursor
position.
• Deleting all numbers
Press the [8
π†
] (CLEAR) button to delete all numbers in the sequence.
6
Press the [F] button to turn the Registration Sequence function on.
7
Press the [DIRECT ACCESS] button, then the [EXIT] button to return to
the Main display and confirm whether the Registration Memory num-
bers are called up according to the sequence programmed above.
• Use the TAB [
®
] button to call up the Registration Memory numbers in the
order of the sequence, or use the TAB [
] button to call them up in
reverse order. The TAB [
][
®
] buttons can only be used for Registration
Sequence when the Main display is called up.
• When pedal operation has been set in step 3, you can use a pedal to select
the Registration Memory numbers in order. The pedal can be used for Reg-
istration Sequence no matter which display is called up (except for the dis-
play in step 3).
Saving the Registration Sequence Settings
The settings for the Sequence order and how Registration Sequence behaves when
reaching the end of the sequence (SEQUENCE END) are included as part of the
Registration Memory Bank file. To store your newly programmed Registration
Sequence, save the current Registration Memory Bank file.
1
Press the REGIST BANK [+] and [–] buttons simultaneously to call up
the REGISTRATION BANK Selection display.
2
Press the [6
] button to save the Bank file (page 73).
CAUTION
Settings in the REGISTRATION
SEQUENCE display are auto-
matically saved to the instru-
ment when you exit from this
display. However, if you turn
the power off without exiting
from this display, the settings
will be lost.
Returning to the first
Sequence in one action
In the Main display, press the
TAB [
] and [
®
] buttons simul-
taneously. This cancels the cur-
rently selected Sequence
number (the box indicator at the
top right goes out). The first
Sequence will be selected by
pressing one of the TAB [
][
®
]
buttons or by pressing the pedal.
The Registration Sequence is indicated at the top
right of the Main display, letting you confirm the
currently selected number.
CAUTION
Keep in mind that all Registra-
tion Sequence data is lost
when changing Registration
Memory Banks, unless you’ve
saved it with the Registration
Memory Bank file.