Adaptec ANA-62022 User Guide - Page 99

Connecting Clients to the NetWare SA, FO, PA, or FEC Server, hkey_local_machine, System

Page 99 highlights

DuraLAN Fast Ethernet NICs User's Guide Connecting Clients to the NetWare SA, FO, PA, or FEC Server For optimum performance of NetWare Duralink64 Failover, all clients (any brand) should increase their IPX retry count. s For DOS clients using VLM or Novell Client32 Type the following lines in edit net.cfg (indenting the second line as shown here): protocol ipx ipx retry count = 255 s For Windows 95 Clients using Novell Client32 From the Control Panel, locate NetWare Clients, and type 255 under the IPX retry count in the IPX 32-bit Protocol tab. s For Windows NT Clients using Novell Client32 Follow these steps to set the IPX retry count in the registry in NetWare Workstation Parameters: a From the DOS prompt, type regedit to enter the Registry Editor. b Double-click hkey_local_machine. c Double-click System. d Double-click CurrentControlSet. e Double-click Services. f Double-click NetWare Workstation. g Double-click Parameters. h Double-click Retry Count to enter the Edit DWORD Value menu. i Change the base to decimal, then change value data to 255. j Click OK. k Close the Registry Editor. l Restart the system. 6-4

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133

6-4
DuraLAN Fast Ethernet NICs User’s Guide
Connecting Clients to the NetWare SA, FO, PA, or FEC
Server
For optimum performance of NetWare Duralink64 Failover, all
clients (any brand) should increase their IPX retry count.
For DOS clients using VLM or Novell Client32
Type the following lines in
edit net.cfg
(indenting the second
line as shown here):
protocol ipx
ipx retry count = 255
For Windows 95 Clients using Novell Client32
From the Control Panel, locate NetWare Clients, and type
255
under the IPX retry count in the IPX 32-bit Protocol tab.
For Windows NT Clients using Novell Client32
Follow these steps to set the IPX retry count in the registry in
NetWare Workstation Parameters:
a
From the DOS prompt, type
regedit
to enter the Registry
Editor.
b
Double-click
hkey_local_machine
.
c
Double-click
System
.
d
Double-click
CurrentControlSet
.
e
Double-click
Services
.
f
Double-click
NetWare Workstation
.
g
Double-click
Parameters
.
h
Double-click
Retry Count
to enter the Edit DWORD Value
menu.
i
Change the base to decimal, then change value data to
255
.
j
Click
OK
.
k
Close the Registry Editor.
l
Restart the system.