<WSW04>, Selectors 6 and 8: Break time length for flash function, Search/Speed Dial
UPC - 012502622673
View all Brother International MFC 8890DW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 443 highlights
Selector No. Function Setting and Specifications 1 Earth function in transfer facility (Not used.) 0: Provided 1: Not provided No. 2 3 2 3 Dual tone detection frequency in ICM recording (Not used.) 0 0: 350 and 440 Hz (A) 0 1: 440 and 480 Hz (B) 1 0: 480 and 620 Hz (C) 1 1: 480 and 620 Hz (C) 4 Dual tone detection sensitivity in ICM recording (Not used.) 0: Normal 1: High Length of time added to time designated by selectors 3 and 4 5 on the WSW 24 (time between 0: Not added 1: +4 seconds added CML ON and pseudo ring backtone return). No. 6 7 8 0 0 0: 80 ms 6 I Break time length for flash function 8 0 0 1: 100 ms 0 1 0: 110 ms 0 1 1: 120 ms 1 0 0: 200 ms 1 0 1: 250 ms 1 1 0: 500 ms 1 1 1: 700 ms Note: • Selectors 1 and 5 through 8 are not applicable in those countries where no transfer facility is supported. • Selectors 6 and 8: Break time length for flash function These selectors set the break time length. This setting is effective only when the flash function is selected for the [Search/Speed Dial] button by using the function switch. App. 1-9 Confidential