Brother International MFC 8890DW Service Manual - Page 481
<WSW40>, Selectors 3 through 8: Masking of symbol rates
UPC - 012502622673
View all Brother International MFC 8890DW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 481 highlights
Selector No. Function 1 Not used. 2 3 I Masking of symbol rate(s) 8 Setting and Specifications Not masking Masking No. 3 0 1 3429 symbols/sec No. 4 0 1 3200 symbols/sec No. 5 0 1 3000 symbols/sec No. 6 0 1 2800 symbols/sec No. 7 - - Not used. No. 8 0 1 2400 symbols/sec Note: • WSW40 takes effect only when the V.34 mode is permitted (WSW19, selector 7) in models supporting V.34 mode. • Selectors 3 through 8: Masking of symbol rate(s) These selectors allow you to limit the transmission speed range in V.34 mode by masking the desired symbol rate(s). Transmission speeds assigned to the symbol rates are listed on the next page. The setting made by these selectors will limit the setting made by selectors 1 through 4 on WSW39. If selector 3 is set to "1" to mask the 3429 symbols/second when the first transmission speed choice is 33600 bps (specified by selectors 1 through 4 of WSW39), for example, then the allowable maximum transmission speed will be limited to 31200 bps. If selector 8 is set to "1" to mask the 2400 symbols/second when the first transmission speed choice is 33600 bps, then the allowable maximum transmission speed remains 33600 bps. If selector 8 is set to "1" to mask the 2400 symbols/second when the first transmission speed choice is 21600 bps (specified by selectors 1 through 4 on WSW39), then the allowable maximum transmission speed remains 21600 bps but the minimum transmission speed will be limited to 4800 bps. App. 1-47 Confidential