Brother International MFC 8890DW Service Manual - Page 454
<WSW14>, Selectors 1 through 4: Frequency band selection for incoming calling signal CI
UPC - 012502622673
View all Brother International MFC 8890DW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 454 highlights
Selector No. Function Setting and Specifications No. 1 2 1 Frequency band selection 0 0: 13 Hz (lower limit) for incoming calling 0 1: 15 Hz 2 signal (CI) 1 0: 23 Hz 1 1: 20 Hz No. 3 4 3 Frequency band selection 0 0: 30 Hz (upper limit) for incoming calling 0 1: 55 Hz 4 signal (CI) 1 0: 70 Hz 1 1: 200 Hz No. 5 6 7 8 0 0 0 0: Fixed to once 0 0 0 1: 1 to 6 times 0 0 1 0: 1 to 8 times 0 0 1 1: 2 to 8 times 0 1 0 0: 1 to 2 times 0 1 0 1: 1 to 3 times 5 0 1 1 0: 1 to 4 times I No. of rings in AUTO ANS mode 0 1 1 1: 1 to 5 times 8 1 0 0 0: 2 to 3 times 1 0 0 1: 2 to 4 times 1 0 1 0: 2 to 5 times 1 0 1 1: 2 to 6 times 1 1 0 0: 1 to 10 times 1 1 0 1: 2 to 10 times 1 1 1 0: 3 to 5 times 1 1 1 1: 4 to 10 times • Selectors 1 through 4: Frequency band selection for incoming calling signal (CI) These selectors are used to select the frequency band of CI for activating the AUTO ANS facility. In the French models, if the user sets the PBX to OFF from the control panel, the setting made by selectors 1 and 2 will take no effect and the frequency's lower limit will be fixed to 32 Hz. (Even if the setting made by these selectors does not apply, it will be printed on the configuration list.) • Selectors 5 through 8: No. of rings in AUTO ANS mode These selectors set the number of rings to initiate the AUTO ANS facility. App. 1-20 Confidential