Brother International MFC 8890DW Service Manual - Page 496
<WSW55>, App. 1-62
UPC - 012502622673
View all Brother International MFC 8890DW manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 496 highlights
Selector No. Function 1 Interval of time required for I the developing bias voltage correction (hour) 8 (Not used.) Setting and Specifications 0: The developing bias voltage correction is performed on each print job. 1-72: The developing bias voltage correction is performed when a print job occurs at specified time or later. 73-254: Not allowed to set. 255 (0xFF): The developing bias voltage correction is not performed. The setting example of the selector number is as follows; No.1 2 3 4 5 6 7 8 0 0 0 0 0 0 0 0 : The developing bias voltage correction is performed on each print job. 0 0 0 1 1 0 0 0 : The developing bias voltage correction is performed when a print job occurs after 24 hours (default value) or later. 0 0 0 1 0 0 1 0 : The developing bias voltage correction is performed when a print job occurs after 72 hours or later. 1 1 1 1 1 1 1 1 : The developing bias voltage correction is not performed. App. 1-62 Confidential