Campbell Scientific CR10 CR10 Measurement and Control - Page 229
Oindex
View all Campbell Scientific CR10 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 229 highlights
CRl O INDEX * Modes, See Modes 1/)( - flnstruction 42) 1O-2 107 Thermistor Probe - flnstruction 111 9-5 Programming examples 7-3 CRl0TCR Thermocouple Reference 7-3 12V terminals OV-3, OV-4 100 ohm PRT 3 wire half bridge 7-8 4 wire half bridge 7-6 4 wire full bridge 7-9 207 Relative Humidity Probe - flnstruction 121 9-6 Programming example 7-4 227 Gypsum Soil Moisture Block 7-13 3 Wire Half Bridge - lnstruction 71 9-4,13-18, 13-19,13-20 Example 7-8 4 Wire Full Bridge - flnstruction 61 9-4, 13-18, 13-19, 13-20 Example 7-9 5th Order Polynomial - flnstruction 55] 10-5 Programming examples 7-14, 7-15 5V outputs OV-3, OV-4, 14-5 A A*X + B, see Scaling Array with Multiplier and Offset - [nstruction 53] A04 Analog Output, see SDM-AO4 A6Rel-1 ?A21Rel12 Relay Driver 1 4-7 ABS(X) - flnstruction 43] 10-3 AC Half Bridge - flnstruction 5l 9-3 Programming examples 7-14, 8-4 Activate Serial Data Output - flnstruction 961 4-1,12-6 lnterrupts during 6-3 Programming examples OV-l7 Using Storage Module with 4-7 Alkaline power supply 14-2 AM416 Multiplexer Measuring soil moisture blocks 8-3 Using control ports and loop 8-3 Analog ground definition OV-3, OV-4 Analog inputs OV-3, OV-4 Analog output, see SDM-A04 Analog to Digital (A/D) conversion 13-1 AND construction, Logical 3-5 Anemometer (Photochopper output) Programming example 7-5 Array lD and Output Interual A-2 Calculating data points 4-6 Definition A-2 Setting lD 2-1, 11-5 ASCII Characters E-1 Definition A-1 Output formats 4-6 Program transfer to computer/printer 1-8 Table E-1 Terminal or computer with terminal emulator OV-9 Table E-1 Transmission 6-7 Asynchronous, Definition A-1 Automatic calibration sequence 13-22 Average - flnstruction 711 11-3 Programming example OV-l6 Average, Computing running 8-1 AVWI/AVW4 Vibrating Wire Interface 7-15 B Battery Power 14-2 Battery Voltage - flnstruction 101 9-5 Baud rate Definition 6-7, A-1 Begin Case Statement - flnstruction 93] 12-5 Binary telecommunications C-l Generation of signature C-4 Block Move - flnstruction 54] 10-4 Programming example 8-1 Bridge measurements 13-17 3 Wire Half Bridge 100 ohm PRT 7-8 4 Wire Full Bridge (Pressure Transducer) 7-10 4 Wire Full Bridge 100 ohm PRT 7-9 4 Wire Half Bridge 100 ohm PRT 7-6 6 Wire Full Bridge (Lysimeter) 7-11 Comparison of bridge measurement instructions 13-18 Diagram of bridge measuring circuits 13-18 with AC excitation 13-19 Bridge Transform - lnstruction 591 10-6 Programming examples 7-1O, 7-14, 8-4 Burst Measurement - [nstruction 23] 9-g c C20 Cassette Interface 4-3 Cables/Leads Avoid PVC insulated conductors 13-10 Connecting Leads to Wiring Panel OV-l l-1