CyberPower PDU41102 User Manual 2 - Page 102

snmpv3 index 1 authkey test_authkey_123456

Page 102 highlights

Commad Line Interface password as test_authkey_123456 CyberPower > snmpv3 index 2 auth md5 authkey test_authkey_123456 Example 6: To change the authentication password of first SNMPv3 user to test_authkey_123456 CyberPower > snmpv3 index 1 authkey test_authkey_123456 Example 7: To change the authentication protocol of third SNMPv3 user to none CyberPower > snmpv3 index 3 auth none Example 8: To change the privacy protocol of second SNMPv3 user to aes and set its privacy password as test_privkey_123456 CyberPower > snmpv3 index 2 priv aes privkey test_privkey_123456 Example 9: To change the privacy password of first SNMPv3 user to test_privkey_123456 CyberPower > snmpv3 index 1 privkey test_privkey_123456 Example 10: To change the privacy protocol of third SNMPv3 user to none CyberPower > snmpv3 index 3 priv none Enter the following command to perform all parameters configuration with a single command: snmpv3 set For example:. CyberPower > snmpv3 set 1 CyberPower 192.168.203.90 sha test_authkey_123456 des test_privkey_123456 trap Description: Show and configure information of SNMP trap receiver. Option show add index name ip Argument 1 | 2 | ... | 10 Description Display trap receiver information. Add trap receiver. Select trap receiver index. Modify trap name of trap receiver. Modify IP address of trap receiver. Intelligent PDU User Guide 100

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

100
Intelligent PDU User Guide
Commad Line Interface
password as
test_authkey_123456
CyberPower >
snmpv3 index 2 auth md5 authkey test_authkey_123456
Example 6:
To change the authentication password of first SNMPv3 user to
test_authkey_123456
CyberPower >
snmpv3 index 1 authkey test_authkey_123456
Example 7:
To change the authentication protocol of third SNMPv3 user to none
CyberPower >
snmpv3 index 3 auth none
Example 8:
To change the privacy protocol of second SNMPv3 user to aes and set its privacy password as
test_privkey_123456
CyberPower >
snmpv3 index 2 priv aes privkey test_privkey_123456
Example 9:
To change the privacy password of first SNMPv3 user to
test_privkey_123456
CyberPower >
snmpv3 index 1 privkey test_privkey_123456
Example 10:
To change the privacy protocol of third SNMPv3 user to none
CyberPower >
snmpv3 index 3 priv none
Enter the following command to perform all parameters configuration with a single command:
snmpv3 set <1 | 2 | 3 | 4> <User Name> <IP Address> <md5 | sha | none> <Auth Key>
<aes | des | none> <Priv Key>
For example:.
CyberPower >
snmpv3 set 1 CyberPower 192.168.203.90 sha test_authkey_123456 des
test_privkey_123456
trap
Description: Show and configure information of SNMP trap receiver.
Option
Argument
Description
show
Display trap receiver information.
add
Add trap receiver.
index
1 | 2 | ... | 10
Select trap receiver index.
name
<Trap Receiver Name>
Modify trap name of trap receiver.
ip
<Trap Receiver IP>
Modify IP address of trap receiver.