CyberPower PDU41102 User Manual 2 - Page 85

Command Lists

Page 85 highlights

Command Lists Commad Line Interface devsta Description: Show device status of load and utility. Option Argument show guest 1 | 2 | 3 Example 1: To display all outlet status CyberPower > devsta show Description Show information of system device load and utility status. Set daisy chain index. devcfg Description: Show and set device load threshold, reset power parameters in device level, set cold start status and delay. Option show guest overload nearover lowload restriction pwrrest coldstasta coldstadly idletime Argument Description Show information of device configuration. 1 | 2 | 3 Set daisy chain index. Set device overload threshold value. Set device near overload threshold value. Set device low load threshold value. none | onnear | onover Set outlet restriction of device. peakload | energy Reset the peak load or energy of device. previous | allon Set the cold start state of device. -1 | 0 | 1 | 2 |...| 300 Set the cold start delay of device. 1 | 2 | 3 | 5 | 10 | never Set idle time of device. Example 1: To display load configuration of the device CyberPower > devcfg show Example 2: To set overload threshold at 15A CyberPower > devcfg overload 15 Example 3: Intelligent PDU User Guide 83

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

83
Intelligent PDU User Guide
Commad Line Interface
Command Lists
devsta
Description: Show device status of load and utility.
Option
Argument
Description
show
Show information of system device load and
utility status.
guest
1 | 2 | 3
Set daisy chain index.
Example 1:
To display all outlet status
CyberPower >
devsta show
devcfg
Description: Show and set device load threshold, reset power parameters in device level, set cold start
status and delay.
Option
Argument
Description
show
Show information of device configuration.
guest
1 | 2 | 3
Set daisy chain index.
overload
<overload threshold value>
Set device overload threshold value.
nearover
<near overload threshold value>
Set device near overload threshold value.
lowload
<low load threshold value>
Set device low load threshold value.
restriction
none | onnear | onover
Set outlet restriction of device.
pwrrest
peakload | energy
Reset the peak load or energy of device.
coldstasta
previous | allon
Set the cold start state of device.
coldstadly
-1 | 0
| 1 | 2 |…
| 300
Set the cold start delay of device.
idletime
1 | 2 | 3 | 5 | 10 | never
Set idle time of device.
Example 1:
To display load configuration of the device
CyberPower >
devcfg show
Example 2:
To set overload threshold at 15A
CyberPower >
devcfg overload 15
Example 3: