CyberPower PDU41102 User Manual 2 - Page 45

Definition, Action Configuration, Instant, Delay, Never, Load Configuration

Page 45 highlights

Outlet Configuration Page Web Interface Item Definition Name The name entered by the user to identify the selected outlet or multiple outlet configuration. Action Configuration Power On/Off Delay *Instant: Turn on/off the outlet immediately. *Delay: Delay time before turning on/off the outlet. Valid values are within the range of 1 to 7,200 seconds. Reboot Duration *Never: Never turn on/off the outlet. The length of time the outlet will remain off during a Reboot action. Valid values are within the range of 5 to 60 seconds. Load Configuration Overload Threshold Set the value for individual outlet that will signal an overload warning in Watts. Must be higher than Near Overload Threshold. Near Overload Threshold Set the value for individual outlet that will signal a near overload warning in Watts. Must be between Overload Threshold and Low Load Threshold. Intelligent PDU User Guide 43

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

43
Web Interface
Intelligent PDU User Guide
Outlet Configuration Page
Item
Definition
Name
The name entered by the user to identify the selected outlet or multiple
outlet configuration.
Action Configuration
Power On/Off
Delay
*Instant
: Turn on/off the outlet immediately.
*Delay
: Delay time before turning on/off the outlet. Valid values
are within the range of 1 to 7,200 seconds.
*Never
: Never turn on/off the outlet.
Reboot Duration
The length of time the outlet will remain off during a Reboot action. Valid
values are within the range of 5 to 60 seconds.
Load Configuration
Overload
Threshold
Set the value for individual outlet that will signal an overload warning in
Watts. Must be higher than
Near Overload Threshold
.
Near Overload
Threshold
Set the value for individual outlet that will signal a near overload
warning in Watts. Must be between
Overload Threshold
and
Low Load
Threshold
.