CyberPower PDU41102 User Manual 2 - Page 88

oltcfg index all show, oltcfg index 1 name test_1, oltcfg index 2 td_on 3, oltcfg index 3 td_off 3,

Page 88 highlights

Commad Line Interface Example 1: To display all outlet configuration CyberPower > oltcfg index all show Example 2: To name outlet #1 as test_1 CyberPower > oltcfg index 1 name test_1 Example 3: To set turn on delay of outlet #2 as 3 seconds CyberPower > oltcfg index 2 td_on 3 Example 4: To set turn off delay of outlet #3 as 3 seconds CyberPower > oltcfg index 3 td_off 3 Example 5: To set reboot duration of outlet #4 as 5 seconds CyberPower > oltcfg index 4 td_reboot 5 Example 6: To name outlet #1 as test_1, set turn on delay as 3 seconds, set turn off delay as 4 seconds and set reboot duration as 5 seconds with a single command CyberPower > oltcfg set 1 test_1 3 4 5 oltloadcfg Description: Show and set outlet load threshold, reset power parameters in outlet level. Option show guest index name overload nearover lowload pwrrest Example 1: Argument Description Show information of Outlet threshold. 1 | 2 | 3 Set daisy chain index. 1 | 2 |...|outlet number | all Select outlet index. Modify outlet name. Set outlet overload threshold value. Set outlet near overload threshold value. Set outlet low load threshold value. peakload | energy Reset the peak load or energy of outlet. Intelligent PDU User Guide 86

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

86
Intelligent PDU User Guide
Commad Line Interface
<0
| 1 | 2 |…
|
7200>
<5 | 6
|…
|
60>
Example 1:
To display all outlet configuration
CyberPower >
oltcfg index all show
Example 2:
To name outlet #1 as test_1
CyberPower >
oltcfg index 1 name test_1
Example 3:
To set turn on delay of outlet #2 as 3 seconds
CyberPower >
oltcfg index 2 td_on 3
Example 4:
To set turn off delay of outlet #3 as 3 seconds
CyberPower >
oltcfg index 3 td_off 3
Example 5:
To set reboot duration of outlet #4 as 5 seconds
CyberPower >
oltcfg index 4 td_reboot 5
Example 6:
To name outlet #1 as test_1, set turn on delay as 3 seconds, set turn off delay as 4 seconds and
set reboot duration as 5 seconds with a single command
CyberPower >
oltcfg set 1 test_1 3 4 5
oltloadcfg
Description: Show and set outlet load threshold, reset power parameters in outlet level.
Option
Argument
Description
show
Show information of Outlet threshold.
guest
1
|
2
|
3
Set daisy chain index.
index
1 | 2 |…
|outlet number |
all
Select outlet index.
name
<outlet name>
Modify outlet name.
overload
<overload threshold value>
Set outlet overload threshold value.
nearover
<near overload threshold value>
Set outlet near overload threshold value.
lowload
<low load threshold value>
Set outlet low load threshold value.
pwrrest
peakload | energy
Reset the peak load or energy of outlet.
Example 1: