Dell Force10 E300 Installing and Maintaining the E300 System - Page 26
WARNING, DC PEM with Cables Installed, This cable is typically green or green and yellow.
View all Dell Force10 E300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
www.dell.com | support.dell.com Step 6 7 8 Task (continued) Secure the chassis ground connection: WARNING: You must complete the ground connection before proceeding with the PEM installation. Locate the chassis ground connector studs on the PEM front panel (see Figure 5-4). The two studs on the upper left are the ground connection. Remove all nuts and washers from the two ground studs. Apply a coat of anti-oxidant paste to the connector studs. Install the grounding cable. This cable is typically green or green and yellow. NOTE: Termination points require UL-listed 2-hole lug with 1/4-inch holes on 3/4-inch spacing. Replace the two washers and nuts on the studs. Secure the nuts with a nut driver or torque wrench (not to exceed 4 ft/lbs). Connect the opposite end of the grounding cable to the appropriate nearest grounding. Remove the outer nut and washer from each of the remaining studs. Connect the -48 VDC and Return cables from each PEM to the remote power sources. Verify that the remote power source is in the OFF position. Locate the appropriate studs on the PEM front panel. The two top studs are the return (+) connection. The cable attached to these studs is typically red. The two bottom studs on the PEM are the -48 VDC (-) connection. The cable attached to these studs is typically black. NOTE: Power cables must be terminated only with a UL-listed 2-hole lug to accommodate 1/4-inch studs with 3/4-inch spacing. Apply a coat of anti-oxidant paste to the connector studs. Replace the washers and nuts on the studs. Route the terminated cables out toward the rack rail (Figure 5-4). Secure the nuts with a nut driver or torque wrench (not to exceed 4 ft/lbs). Figure 5-4. DC PEM with Cables Installed MAKE GROUND CONNECTION FIRST CAUTION - Use conductors only copper Ground cable, typically green or green with yellow stripes ( ) Return cable, typically red (-) -48V cable, typically black Over-current protector switch 9 Replace the safety cover and tighten the captive screw with a #2 Phillips screwdriver. 10 Turn the Over Current Protector to the ON position (Figure 5-4). 11 Turn the remote power source (the circuit breaker panel) to the ON position. 26 | Installing Power Modules