Dell PowerEdge 1655MC Information and Firmware Update - Page 10

Globally Updating the Server Module KVM Firmware - blade

Page 10 highlights

www.dell.com | support.dell.com Globally Updating the Server Module KVM Firmware 1 Ensure that all server modules are powered on. When the server module is on, the power-on indicator is solid green. 2 Press to display the On-Screen Configuration and Activity Reporting (OSCAR) menu. 3 From the OSCAR menu, click Commands. 4 From the Commands dialog box, click Blade Status. NOTICE: To prevent damage to the system, do not turn the power off once the update process has begun. 5 From the Blade Status dialog box, click Update to begin updating all of the server modules. As a server module is being updated, the green dot on the OSCAR menu indicating that the server module is powered on turns amber. After the server module has been updated, the dot turns back to green and the update process begins on the next server module. Individually Updating the Server Module KVM Firmware 1 Ensure that all server modules are powered on. When the server module is on, the power-on indicator is solid green. 2 Press to display the OSCAR menu. 3 From the OSCAR menu, click Commands. 4 From the Commands dialog box, click Display Versions. 5 From the Version dialog box, click Blade. 6 From the Blade Selection dialog box, highlight the appropriate server module and click Version. NOTICE: To prevent damage to the system, do not turn the power off once the update process has begun. 7 From the Blade Version dialog box, click Load Firmware to begin the process of updating the selected server module. As the server module is being updated, the green dot indicating that the server module is powered on turns amber. After the server module has been updated, the dot turns back to green. 1-6 Information and Firmware Update

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170

1-6
Information and Firmware Update
www.dell.com | support.dell.com
Globally Updating the Server Module KVM Firmware
1
Ensure that all server modules are powered on.
When the server module is on, the power-on indicator is solid green.
2
Press <Print Screen> to display the On-Screen Configuration and Activity Reporting
(OSCAR) menu.
3
From the OSCAR menu, click
Commands
.
4
From the
Commands
dialog box, click
Blade Status
.
NOTICE:
To prevent damage to the system, do not turn the power off once the update process
has begun.
5
From the
Blade Status
dialog box, click
Update
to begin updating all of the server
modules.
As a server module is being updated, the green dot on the OSCAR menu indicating
that the server module is powered on turns amber. After the server module has been
updated, the dot turns back to green and the update process begins on the next server
module.
Individually Updating the Server Module KVM Firmware
1
Ensure that all server modules are powered on.
When the server module is on, the power-on indicator is solid green.
2
Press <Print Screen> to display the OSCAR menu.
3
From the OSCAR menu, click
Commands
.
4
From the
Commands
dialog box, click
Display Versions
.
5
From the
Version
dialog box, click
Blade
.
6
From the
Blade Selection
dialog box, highlight the appropriate server module and
click
Version
.
NOTICE:
To prevent damage to the system, do not turn the power off once the update process
has begun.
7
From the
Blade Version
dialog box, click
Load Firmware
to begin the process of
updating the selected server module.
As the server module is being updated, the green dot indicating that the server module
is powered on turns amber. After the server module has been updated, the dot turns