Dell PowerEdge 1655MC Information and Firmware Update - Page 16
Orient the server module as shown in so that the two captive screws are
View all Dell PowerEdge 1655MC manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 16 highlights
www.dell.com | support.dell.com CAUTION: There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the manufacturer's instructions. See your System Information Guide for additional information. 1 Remove the appropriate server module. 2 Open the server module. a Orient the server module as shown in Figure 1-4 so that the two captive screws are on the left side of the server module. b Using a #2 Phillips screwdriver, loosen the two captive screws that secure the front panel to the server module (see Figure 1-4). c Slide the left side of the server module backward approximately 12.7 mm (0.5 inch) and rotate the two sides down to open the server module (see Figure 1-4). Figure 1-4. Opening and Closing a Server Module left side server module captive screws (2) server module handle right side 1-12 Information and Firmware Update