Page 105 highlights

Error Code PCI3004 PCI3006 PCI3008 PCI3010 PCI3012 PCI3014 Message Information Details Action Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and does not support FlexAddress. Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If the issue persists, see Getting Help. Message Details Action Device option ROM on mezzanine card failed to support Link Tuning or FlexAddress. Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of date and does not support FlexAddress. Update BIOS, BMC/iDRAC, and mezzanine card firmware. If the issue persists, see Getting Help. Message Details Action Failed to get Link Tuning or FlexAddress data from iDRAC. Either the BIOS or BMC/iDRAC firmware is out of date and does not support FlexAddress. Update BIOS, and BMC/iDRAC firmware. If the issue persists, see Getting Help. Message Details Action A non-fatal PCIe error detected on a component at bus devicefunction . System performance may be degraded. Cycle input power, update component drivers, remove and reinstall the device at the next service window. Message Details Action A non-fatal IO error detected on a component at bus devicefunction . System performance may be degraded. Cycle input power, update component drivers, remove and reinstall the device at the next service window. Message Details Action The QuickPath Interconnect (QPI) width degraded. System performance may be degraded. The bus is not operating at maximum speed or width. Reset the system, if the problem persists reinstall processors. Message Details A non-fatal PCIe error detected on a component at slot . System performance may be degraded. 105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

Error Code
Message Information
Details
Either the BIOS, BMC/iDRAC, LOM, or NIC firmware is out of date and
does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, LOM, and mezzanine card firmware. If the
issue persists, see
Getting Help
.
PCI3004
Message
Device option ROM on mezzanine card <
number
> failed to support
Link Tuning or FlexAddress.
Details
Either the BIOS, BMC/iDRAC, or mezzanine card firmware is out of
date and does not support FlexAddress.
Action
Update BIOS, BMC/iDRAC, and mezzanine card firmware. If the issue
persists, see
Getting Help
.
PCI3006
Message
Failed to get Link Tuning or FlexAddress data from iDRAC.
Details
Either the BIOS or BMC/iDRAC firmware is out of date and does not
support FlexAddress.
Action
Update BIOS, and BMC/iDRAC firmware. If the issue persists, see
Getting Help
.
PCI3008
Message
A non-fatal PCIe error detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall
the device at the next service window.
PCI3010
Message
A non-fatal IO error detected on a component at bus
<
bus
>device<
device
>function <
func
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall
the device at the next service window.
PCI3012
Message
The QuickPath Interconnect (QPI) width degraded.
Details
System performance may be degraded. The bus is not operating at
maximum speed or width.
Action
Reset the system, if the problem persists reinstall processors.
PCI3014
Message
A non-fatal PCIe error detected on a component at slot <
number
>.
Details
System performance may be degraded.
105