Dell PowerEdge M620 Owners Manual - Page 82
Bay ID, number, Review System Event Log and Operating System Logs. If the issue
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 82 highlights
Error Code BAT0015 BAT0017 BAT0019 CBL0006 CPU0000 CPU0001 82 Message Information LCD Message Details Action Battery for disk drive bay is absent. Check battery. Verify the cable connection between the storage battery and the controller. Verify the storage battery installation. Message Details Action The battery is low. The low battery may impact system performance negatively. Recharge the battery if possible. If the problem continues replace the battery. Message LCD Message Details Action The battery has failed. The battery has failed. Check battery. The battery is either missing, bad, or unable to charge due to thermal issues. Check system fans. Replace the battery. Message LCD Message Details Action The battery is absent. The battery is absent. Check battery. The failed or missing battery may reduce system performance. Check system fans. Replace the battery. Message Details Action Multiple storage controllers are incorrectly connected to the same backplane . Unsupported backplane configuration. Check backplane configuration. Reconnect cable. If the issue persists, see Getting Help. Message LCD Message Details Action CPU has an internal error (IERR). CPU has an internal error (IERR). System event log and OS logs may indicate that the exception is external to the processor. Review System Event Log and Operating System Logs. If the issue persists, see Getting Help. Message CPU has a thermal trip (over-temperature) event.