Dell PowerEdge M620 Owners Manual - Page 106
The controller detected a drive removal., If unintended, verify drive installation.
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 106 highlights
Error Code PDR0001 PDR0002 PDR0016 PDR1001 PDR1002 PDR1016 106 Message Information Action Cycle input power, update component drivers, remove and reinstall the device at the next scheduled service time. Message LCD Message Details Action Fault detected on drive . Fault detected on drive . Check drive. The controller detected a failure on the disk and has taken the disk offline. Remove and re-seat the failed disk. If the issue persists, see Getting Help. Message Details Action A predictive failure detected on drive . The controller received a SMART error from the drive. The drive is operational but needs replacement. The drive will need replacement at the next service window. Message LCD Message Details Action Drive is removed. Drive is removed. Check drive. The controller detected a drive removal. If unintended, verify drive installation. Remove and re-seat the indicated disk. If the issue persists, see Getting Help. Message LCD Message Details Action Fault detected on drive in disk drive bay . Fault detected on drive in disk drive bay . Check drive. The controller detected a failure on the disk and has taken the disk offline. Re-seat the failed drive. If the issue persists, see Getting Help. Message Details Action A predictive failure detected on drive in disk drive bay. The controller received a SMART error from the drive. The drive is operational but needs replacement. The drive will need replacement at the next service window. Message LCD Message Drive is removed from disk drive bay . Drive removed from disk drive bay . Check drive.