Dell PowerEdge M620 Owners Manual - Page 132
The system board <, reinstall system cables.
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 132 highlights
Error Code VLT0200 VLT0201 VLT0202 132 Message Information Details Action System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. Message LCD Message Details Action The system board voltage is less than the lower critical threshold. System board voltage is outside of range. System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. Message LCD Message Details Action The system board voltage is less than the lower warning threshold. System board voltage is outside of range. System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Re-configure the system to minimum configuration, inspect and reinstall system cables. 3. If the issue persists, see Getting Help. Message LCD Message The system board voltage is greater than the upper warning threshold. System board voltage is outside of range.