> voltage regulator module failed. Re-seat module.
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 88 highlights
Error Code CPU0704 CPU0801 CPU0802 CPU0803 Message Information Message LCD Message Details Action CPU machine check error detected. CPU machine check error detected. Power cycle system. System event log and operating system logs may indicate that the exception is external to the processor. 1. Check system and operating system logs for exceptions. If no exceptions are found, continue. 2. Turn system off and remove input power for one minute. 3. Ensure the processor is seated correctly. 4. Reapply input power and turn system on. 5. If the issue persists, see Getting Help. Message LCD Message Details Action CPU voltage regulator module failed. CPU voltage regulator module failed. Re-seat module. System performance may be degraded or the system may fail to operate. 1. Turn system off and remove input power for one minute. 2. Reapply input power and turn system on. 3. Ensure the processor is seated correctly. 4. If the issue persists, see Getting Help. Message Details Action A predictive failure detected on CPU voltage regulator module. System performance may be degraded or the system may fail to operate. 1. Turn system off and remove input power for one minute. 2. Reapply input power and turn system on. 3. Ensure the processor is seated correctly. 4. If the issue persists, see Getting Help. Message LCD Message Details The power input for CPU voltage regulator module is lost. Lost power input for CPU voltage regulator module. Re-seat module. System performance may be degraded or the system may fail to operate. 88