Dell PowerEdge M620 Owners Manual - Page 131
> voltage is greater than the upper critical, > voltage is outside of the allowable range.
View all Dell PowerEdge M620 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 131 highlights
Error Code VLT0102 VLT0103 VLT0104 Message Information Details Action System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. Message LCD Message Details Action Processor module voltage is greater than the upper warning threshold. Processor module voltage is outside of range. System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. Message LCD Message Details Action Processor module voltage is greater than the upper critical threshold. Processor module voltage is outside of range. System hardware detected an over voltage or under voltage condition. If multiple voltage exceptions occur consecutively the system may power down in fail-safe mode. 1. Review system logs for power supply exceptions. 2. Remove the processor module. Inspect processor socket for bent pins. 3. If the issue persists, see Getting Help. Message LCD Message Processor module voltage is outside of the allowable range. Processor module voltage is outside of range. 131