Dell PowerEdge M620 Owners Manual - Page 81

Getting Help, Getting, Verify the cable connection between the storage battery and

Page 81 highlights

Error Code BAT0002 BAT0004 BAT0005 BAT0007 BAT0010 BAT0012 BAT0014 Message Information Details Action The system board battery is either missing, bad, or unable to charge due to thermal issues. Check system fans. Replace the system board battery. Message LCD Message Details Action The system board battery has failed. The system board battery has failed. Check battery. The system board battery is either missing or bad. See Getting Help. Message LCD Message Action The system board battery is absent. The system board battery is absent. Check battery. Reinstall the system board battery. Message Details Action The storage battery is low. System has to remain powered on to charge the battery. Allow the battery to charge. If the issue persists, see Getting Help. Message LCD Message Details Action The storage battery has failed. The storage battery has failed. Check battery. Verify the cable connection between the storage battery and the controller. Verify the storage battery installation. Message Details Action The storage battery for disk drive bay is low. System has to remain powered on to charge the storage battery. Allow the storage battery to charge. If the issue persists, see Getting Help. Message LCD Message Details Action The storage battery for disk drive bay has failed. Battery for disk drive bay has failed. Check battery. Verify the cable connection between the storage battery and the controller. Verify the storage battery installation. Message The storage battery for disk drive bay is absent. 81

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143

Error Code
Message Information
Details
The system board battery is either missing, bad, or unable to charge
due to thermal issues.
Action
Check system fans. Replace the system board battery.
BAT0002
Message
The system board battery has failed.
LCD Message
The system board battery has failed. Check battery.
Details
The system board battery is either missing or bad.
Action
See
Getting Help
.
BAT0004
Message
The system board battery is absent.
LCD Message
The system board battery is absent. Check battery.
Action
Reinstall the system board battery.
BAT0005
Message
The storage battery is low.
Details
System has to remain powered on to charge the battery.
Action
Allow the battery to charge. If the issue persists, see
Getting Help
.
BAT0007
Message
The storage battery has failed.
LCD Message
The storage battery has failed. Check battery.
Details
Verify the cable connection between the storage battery and the
controller.
Action
Verify the storage battery installation.
BAT0010
Message
The storage battery for disk drive bay <
bay
> is low.
Details
System has to remain powered on to charge the storage battery.
Action
Allow the storage battery to charge. If the issue persists, see
Getting
Help
.
BAT0012
Message
The storage battery for disk drive bay <
bay
> has failed.
LCD Message
Battery for disk drive bay <
bay
> has failed. Check battery.
Details
Verify the cable connection between the storage battery and the
controller.
Action
Verify the storage battery installation.
BAT0014
Message
The storage battery for disk drive bay <
bay
> is absent.
81